Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Éclairage de salle blanche et équipements électriques

Transformateur d'isolation

A dry-type transformer that provides galvanic separation, voltage adaptation and optional electrostatic shielding for sensitive cleanroom loads.
  • Galvanically Isolated Windings
  • Low-Noise Laminated Core
  • Electrostatic Shield Option
  • Enclosed Finger-Safe Terminals
Demander un devis. Browse les produits

Introduction de produit

The isolation transformer uses separate primary and secondary windings on a laminated magnetic core. Encapsulated or varnish-impregnated coils resist moisture and vibration, and an optional copper electrostatic shield is bonded to earth between windings to attenuate common-mode noise. The assembly is housed in a non-ventilated or guarded enclosure with clearly separated input and output terminals.

Key Features

Physically separate windings prevent a direct conductive path between input and output.

Encapsulated coils support consistent insulation and lower audible vibration.

An interwinding shield diverts coupled high-frequency noise to protective earth.

Finger-safe terminal blocks organize primary taps and secondary connections.

Rubber isolation mounts reduce mechanical hum transmitted to the floor or wall.

Préoccupations du client produit

Sensitive equipment can be affected by ground noise, voltage mismatch and transformer hum even when the nominal supply remains available.

Common-mode electrical noise enters instrument reference circuits.Galvanic separation and an optional grounded shield reduce capacitive noise transfer.
A transformer enclosure transmits audible hum into a quiet laboratory.A welded core, coil impregnation and resilient mounting pads limit vibration.
Exposed terminal studs create accidental-contact risk.A guarded wiring compartment uses labeled finger-safe connectors.
Dust enters an open ventilated enclosure near a clean process.An encapsulated non-ventilated configuration closes the core and coil from room air.

Les applications typiques

Sensitive analytical instrumentsCleanroom control powerMedical-device test benchesNoise-sensitive monitoring systems

Paramètres techniques

Typical configurable construction ranges for an isolation transformer are listed below.

Matériaux de baseGrain-oriented silicon-steel core with separate copper windings, insulation system and optional copper electrostatic shield
Panneau épaisseur200-650 mm enclosed transformer depth
Largeur effective250-900 mm cabinet width
Longueur maximaleUp to 1200 mm overall enclosure height
Acier face épaisseur1.0-2.0 mm powder-coated steel or stainless enclosure
Densité CoreApproximately 7600-7700 kg/m³ for laminated electrical steel core material
Conductivité thermique20-30 W/(m·K) for laminated silicon steel across the core assembly
surface finieLight-grey or white powder-coated enclosure with copper earth and terminal markings
Type jointBolted or welded core-and-coil assembly on resilient mounts with segregated terminal compartment
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

Single- or three-phase designEncapsulated or ventilated dry typeElectrostatic shieldInput and output voltage tap selection

Planning a Isolation Transformer specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe
Email nous WhatsApp WeChat

Accueil

Produits

Actualités

À propos

Contact