Módulo integrado de suprimento de ar limpo HEPA
- Balanced Ducted Supply
- HEPA or ULPA Final Stage
- Room-Side Test Access
- Interchangeable Diffuser
Introdução do produto
The integrated HEPA clean air supply module receives conditioned air through a top or side duct collar and distributes it across a sealed final filter through an internal equalization plenum. A balancing damper can be adjusted from the cleanroom side, while separate upstream pressure and aerosol ports support routine checks without opening the ceiling void. The module includes the filter seat, retaining hardware and removable perforated or radial diffuser, so the complete air terminal can be installed as one coordinated ceiling component rather than assembled from unrelated parts on site.
Características-chave
Room-side damper access allows supply volume to be balanced after ceiling installation.
Separate upstream pressure and challenge ports keep routine test connections accessible below the ceiling.
A quick-release face accepts different diffuser patterns without replacing the sealed plenum.
Preocupações do produto do cliente
A cleanroom supply point must convert uneven duct air into a sealed, testable and draught-controlled final discharge without consuming unnecessary ceiling space.
Aplicações típicas
Parâmetros técnicos
Representative construction ranges for an integrated ducted HEPA clean-air supply module are listed below.
| Material principal | Welded pressure plenum with micro-glass H13-H14 HEPA or optional ULPA mini-pleat filter |
|---|---|
| Painel de espessura | 250-450 mm overall module depth excluding the duct collar |
| Largura efetiva | 575-1175 mm nominal ceiling-module width |
| Comprimento máximo | Up to 1175 mm standard module length |
| Aço enfrentando espessura | 0.8-1.2 mm welded powder-coated steel or 304 stainless-steel plenum |
| Densidade Core | Approximately 90-120 kg/m³ compacted density of the mini-pleat pack integrated into the clean-air supply module |
| Condutividade térmica | Approximately 0.035-0.043 W/(m·K) for the mini-pleat pack installed in the integrated clean-air supply module |
| Superfície acabado | Cleanroom-white epoxy-polyester powder coat or brushed 304 stainless steel |
| Tipo conjunto | Welded plenum with gasketed duct collar, compression or gel filter seat and sealed T-grid perimeter |
| Customização | Disponível com base na aplicação pretendida e no ambiente operacional. |
Opções disponíveis
Planning a Integrated HEPA Clean Air Supply Module specification?
Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Inglês
Alemão
Língua árabe
Francês
Língua indonésia
Japonês
Coreano
Língua malaia
Portuguêsatual
Língua russa
Espanhol
Tailandês
Língua turca
Vietnã