Módulo integrado de suministro de aire limpio HEPA
- Balanced Ducted Supply
- HEPA or ULPA Final Stage
- Room-Side Test Access
- Interchangeable Diffuser
Introducción del producto
The integrated HEPA clean air supply module receives conditioned air through a top or side duct collar and distributes it across a sealed final filter through an internal equalization plenum. A balancing damper can be adjusted from the cleanroom side, while separate upstream pressure and aerosol ports support routine checks without opening the ceiling void. The module includes the filter seat, retaining hardware and removable perforated or radial diffuser, so the complete air terminal can be installed as one coordinated ceiling component rather than assembled from unrelated parts on site.
Características clave
Room-side damper access allows supply volume to be balanced after ceiling installation.
Separate upstream pressure and challenge ports keep routine test connections accessible below the ceiling.
A quick-release face accepts different diffuser patterns without replacing the sealed plenum.
Preocupaciones del producto del cliente
A cleanroom supply point must convert uneven duct air into a sealed, testable and draught-controlled final discharge without consuming unnecessary ceiling space.
Aplicaciones típicas
Parámetros técnicos
Representative construction ranges for an integrated ducted HEPA clean-air supply module are listed below.
| Materiales Core | Welded pressure plenum with micro-glass H13-H14 HEPA or optional ULPA mini-pleat filter |
|---|---|
| Panel de espesor | 250-450 mm overall module depth excluding the duct collar |
| Ancho efectivo | 575-1175 mm nominal ceiling-module width |
| Longitud máxima | Up to 1175 mm standard module length |
| Acero frente a espesor | 0.8-1.2 mm welded powder-coated steel or 304 stainless-steel plenum |
| Densidad Core | Approximately 90-120 kg/m³ compacted density of the mini-pleat pack integrated into the clean-air supply module |
| Conductividad térmica | Approximately 0.035-0.043 W/(m·K) for the mini-pleat pack installed in the integrated clean-air supply module |
| Superficie acabada | Cleanroom-white epoxy-polyester powder coat or brushed 304 stainless steel |
| Tipo conjunto | Welded plenum with gasketed duct collar, compression or gel filter seat and sealed T-grid perimeter |
| Customization | Disponible según la aplicación prevista y el entorno operativo. |
Opciones disponibles
Planning a Integrated HEPA Clean Air Supply Module specification?
Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Inglés
Alemán
El árabe
Francés
Idioma indonesio
El japonés
Coreano
El malayo
El portugués
El ruso
EspañolCurrent
Tailandés
El turco
El vietnamita