클린룸 장비 및 무균 시설 필수품의 원스톱 공급업체국제 프로젝트 지원
Open mobile navigationClose mobile navigation
/ 제품 / FFU 및 터미널 공기 정화 장비 / Integrated HEPA Clean Air Supply Module
FFU 및 터미널 공기 정화 장비

통합 HEPA 청정 공기 공급 모듈

A complete ducted ceiling terminal combining an inlet damper, pressure-equalizing plenum, sealed HEPA or ULPA filter and room-side diffuser in one cleanable module.
  • Balanced Ducted Supply
  • HEPA or ULPA Final Stage
  • Room-Side Test Access
  • Interchangeable Diffuser
견적 요청 제품 찾아보기

상품 소개

The integrated HEPA clean air supply module receives conditioned air through a top or side duct collar and distributes it across a sealed final filter through an internal equalization plenum. A balancing damper can be adjusted from the cleanroom side, while separate upstream pressure and aerosol ports support routine checks without opening the ceiling void. The module includes the filter seat, retaining hardware and removable perforated or radial diffuser, so the complete air terminal can be installed as one coordinated ceiling component rather than assembled from unrelated parts on site.

주요 기능

An internal equalization chamber spreads duct velocity before air reaches the full filter face.

Room-side damper access allows supply volume to be balanced after ceiling installation.

Separate upstream pressure and challenge ports keep routine test connections accessible below the ceiling.

A quick-release face accepts different diffuser patterns without replacing the sealed plenum.

고객 제품 관심사

A cleanroom supply point must convert uneven duct air into a sealed, testable and draught-controlled final discharge without consuming unnecessary ceiling space.

High inlet velocity loads one part of the HEPA face and leaves another area underused.The pressure-equalizing plenum diffuses the incoming jet before it enters the final filter.
Ceiling access is obstructed by services when the airflow damper needs adjustment.A room-side adjustment mechanism reaches the inlet damper through the removable diffuser.
Temporary hoses for filter testing are routed through the occupied ceiling void.Dedicated room-side pressure and aerosol ports connect directly to the upstream plenum.
One discharge pattern creates local draughts after the room layout changes.Perforated, swirl or radial front plates can be exchanged while the terminal body remains installed.

일반적인 응용 프로그램

제약 생산 제품군Hospital clean treatment rooms생명공학 연구소 (Biotechnology Laboratories)Medical-device assembly areasDucted microelectronics cleanrooms

기술 매개변수

Representative construction ranges for an integrated ducted HEPA clean-air supply module are listed below.

핵심 재료Welded pressure plenum with micro-glass H13-H14 HEPA or optional ULPA mini-pleat filter
패널 두께250-450 mm overall module depth excluding the duct collar
유효 폭575-1175 mm nominal ceiling-module width
최대 길이Up to 1175 mm standard module length
강철 면면 두께0.8-1.2 mm welded powder-coated steel or 304 stainless-steel plenum
코어 밀도Approximately 90-120 kg/m³ compacted density of the mini-pleat pack integrated into the clean-air supply module
열전도도 (Thermal Conductivity)Approximately 0.035-0.043 W/(m·K) for the mini-pleat pack installed in the integrated clean-air supply module
표면 마무리Cleanroom-white epoxy-polyester powder coat or brushed 304 stainless steel
접합 유형Welded plenum with gasketed duct collar, compression or gel filter seat and sealed T-grid perimeter
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

사용 가능한 옵션

Top or side duct collarManual or room-side adjustable inlet damperH13, H14 or ULPA final filterPerforated, radial or swirl diffuser

Planning a Integrated HEPA Clean Air Supply Module specification?

치수, 설치 조건, 성능 목표 및 필요한 표면 마감을 보내십시오.

우리 팀과 대화하십시오.