Интегрированный модуль снабжения чистым воздухом HEPA
- Balanced Ducted Supply
- HEPA or ULPA Final Stage
- Room-Side Test Access
- Interchangeable Diffuser
Введение продукции
The integrated HEPA clean air supply module receives conditioned air through a top or side duct collar and distributes it across a sealed final filter through an internal equalization plenum. A balancing damper can be adjusted from the cleanroom side, while separate upstream pressure and aerosol ports support routine checks without opening the ceiling void. The module includes the filter seat, retaining hardware and removable perforated or radial diffuser, so the complete air terminal can be installed as one coordinated ceiling component rather than assembled from unrelated parts on site.
Основные характеристики
Room-side damper access allows supply volume to be balanced after ceiling installation.
Separate upstream pressure and challenge ports keep routine test connections accessible below the ceiling.
A quick-release face accepts different diffuser patterns without replacing the sealed plenum.
Обеспокоенность клиентов продуктами
A cleanroom supply point must convert uneven duct air into a sealed, testable and draught-controlled final discharge without consuming unnecessary ceiling space.
Типичные приложения
Технические параметры
Representative construction ranges for an integrated ducted HEPA clean-air supply module are listed below.
| Основной материал | Welded pressure plenum with micro-glass H13-H14 HEPA or optional ULPA mini-pleat filter |
|---|---|
| Толщина панели | 250-450 mm overall module depth excluding the duct collar |
| эффективная ширина | 575-1175 mm nominal ceiling-module width |
| Максимальная длина | Up to 1175 mm standard module length |
| Толщина линий стали | 0.8-1.2 mm welded powder-coated steel or 304 stainless-steel plenum |
| Плотность ядра | Approximately 90-120 kg/m³ compacted density of the mini-pleat pack integrated into the clean-air supply module |
| Теплопроводимость | Approximately 0.035-0.043 W/(m·K) for the mini-pleat pack installed in the integrated clean-air supply module |
| Поверхностная отделка | Cleanroom-white epoxy-polyester powder coat or brushed 304 stainless steel |
| Объединенный тип | Welded plenum with gasketed duct collar, compression or gel filter seat and sealed T-grid perimeter |
| Customization | Доступно в зависимости от предполагаемого применения и операционной среды. |
Доступные варианты
Planning a Integrated HEPA Clean Air Supply Module specification?
Отправьте нам ваши габариты, условия монтажа, целевые показатели производительности и требуемую отделку поверхности.