Seu fornecedor único para equipamentos de sala limpa e instalações assépticas essenciaisApoio Internacional a Projetos
Open mobile navigationClose mobile navigation
Limpeza, desinfecção e esterilização da sala limpa

Z Esterilizador de calor seco

A batch dry-heat sterilization and depyrogenation oven with high-temperature recirculation, filtered chamber air, programmable thermal cycles, and controlled cooling.
  • Uniform forced-air heating supports repeatable dry-heat cycles
  • High-temperature filtration controls particles during heating and cooling
  • Interlocked insulated doors protect operators and process zones
Solicite um orçamento. Browse produtos

Introdução do produto

This dry heat sterilizer is intended for glassware, metal tools, components, and other heat-tolerant loads. The insulated chamber, recirculation path, high-temperature filters, and programmable controller support batch sterilization or depyrogenation workflows. Chamber size, door arrangement, loading rack, temperature range, and cooling system are selected for the process.

Características-chave

304 or 316L stainless-steel chamber

Forced recirculation with high-temperature fans

High-temperature HEPA filtration option

Multiple chamber temperature sensors

Programmable heat-up, exposure, and cooling stages

Door-temperature safety interlock

Single- or double-door configuration

Validation-probe access port and cycle records

Preocupações do produto do cliente

Dry-heat processing requires stable temperature distribution throughout the load and careful control during cooling. Poor airflow, excessive loading, filter degradation, or premature door opening can compromise repeatability and particle control.

How is temperature uniformity managed?Engineered recirculation, distributed sensors, controlled ramp rates, and load-specific mapping establish the operating recipe.
How are particles controlled during cooling?Filtered recirculation continues through critical phases, with compatible high-temperature filters selected for the process.
Can doors open while the chamber is hot?Safety logic prevents release until the chamber meets the configured temperature and cycle-status conditions.
Can process data be retained?The controller records temperature channels, phase times, alarms, and completion status for export or network integration.

Aplicações típicas

Pharmaceutical glassware and componentsVials, containers, and metal toolsLaboratory heat-stable loadsAseptic production supportBatch depyrogenation processesBiotechnology manufacturing

Parâmetros técnicos

Electric heaters and high-temperature circulation fans drive filtered air through a stainless chamber. Multiple temperature sensors regulate ramp, exposure, and cooling stages. Single- or double-door versions can maintain controlled airflow and pressure relationships between loading and unloading areas.

Material principal304 or 316L stainless-steel chamber with high-temperature heater and fan components
Painel de espessura80–150 mm thermally insulated oven panels
Largura efetiva700–1600 mm chamber or cabinet width
Comprimento máximo1500–3000 mm maximum external dimension
Aço enfrentando espessura1.0–1.5 mm stainless-steel facing
Densidade Core80–140 kg/m³ high-temperature mineral insulation
Condutividade térmica0.040–0.060 W/(m·K)
Superfície acabadoBrushed exterior stainless steel with smooth polished chamber interior
Tipo conjuntoContinuously welded chamber seams with high-temperature gasketed interlocked doors
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Opções disponíveis

Single or double interlocked doors304 or 316L chamberHigh-temperature HEPA filtersWater-cooled heat exchangerLoading racks and transfer trolleysAdditional validation probesSCADA or MES communication

Planning a Dry Heat Sterilizer specification?

Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Fale com a nossa equipe
Email-nos O WhatsApp WeChat

Início

Produtos

Notícias

Sobre nós

Contato