Su proveedor de ventanilla única para equipos de sala limpia y elementos esenciales para instalaciones asépticasApoyo a proyectos internacionales
Open mobile navigationClose mobile navigation
Limpieza de sala limpia, desinfección y esterilización

Esterilizador de calor seco

A batch dry-heat sterilization and depyrogenation oven with high-temperature recirculation, filtered chamber air, programmable thermal cycles, and controlled cooling.
  • Uniform forced-air heating supports repeatable dry-heat cycles
  • High-temperature filtration controls particles during heating and cooling
  • Interlocked insulated doors protect operators and process zones
Solicite un presupuesto. Browse productos

Introducción del producto

This dry heat sterilizer is intended for glassware, metal tools, components, and other heat-tolerant loads. The insulated chamber, recirculation path, high-temperature filters, and programmable controller support batch sterilization or depyrogenation workflows. Chamber size, door arrangement, loading rack, temperature range, and cooling system are selected for the process.

Características clave

304 or 316L stainless-steel chamber

Forced recirculation with high-temperature fans

High-temperature HEPA filtration option

Multiple chamber temperature sensors

Programmable heat-up, exposure, and cooling stages

Door-temperature safety interlock

Single- or double-door configuration

Validation-probe access port and cycle records

Preocupaciones del producto del cliente

Dry-heat processing requires stable temperature distribution throughout the load and careful control during cooling. Poor airflow, excessive loading, filter degradation, or premature door opening can compromise repeatability and particle control.

How is temperature uniformity managed?Engineered recirculation, distributed sensors, controlled ramp rates, and load-specific mapping establish the operating recipe.
How are particles controlled during cooling?Filtered recirculation continues through critical phases, with compatible high-temperature filters selected for the process.
Can doors open while the chamber is hot?Safety logic prevents release until the chamber meets the configured temperature and cycle-status conditions.
Can process data be retained?The controller records temperature channels, phase times, alarms, and completion status for export or network integration.

Aplicaciones típicas

Pharmaceutical glassware and componentsVials, containers, and metal toolsLaboratory heat-stable loadsAseptic production supportBatch depyrogenation processesBiotechnology manufacturing

Parámetros técnicos

Electric heaters and high-temperature circulation fans drive filtered air through a stainless chamber. Multiple temperature sensors regulate ramp, exposure, and cooling stages. Single- or double-door versions can maintain controlled airflow and pressure relationships between loading and unloading areas.

Materiales Core304 or 316L stainless-steel chamber with high-temperature heater and fan components
Panel de espesor80–150 mm thermally insulated oven panels
Ancho efectivo700–1600 mm chamber or cabinet width
Longitud máxima1500–3000 mm maximum external dimension
Acero frente a espesor1.0–1.5 mm stainless-steel facing
Densidad Core80–140 kg/m³ high-temperature mineral insulation
Conductividad térmica0.040–0.060 W/(m·K)
Superficie acabadaBrushed exterior stainless steel with smooth polished chamber interior
Tipo conjuntoContinuously welded chamber seams with high-temperature gasketed interlocked doors
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

Single or double interlocked doors304 or 316L chamberHigh-temperature HEPA filtersWater-cooled heat exchangerLoading racks and transfer trolleysAdditional validation probesSCADA or MES communication

Planning a Dry Heat Sterilizer specification?

Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Habla con nuestro equipo
E-mail Nos WhatsApp WeChat

Inicio

Productos

Noticias

Nosotros

Contacto