Seu fornecedor único para equipamentos de sala limpa e instalações assépticas essenciaisApoio Internacional a Projetos
Open mobile navigationClose mobile navigation
Fluxo laminar e equipamentos de contenção

Gabinete de Segurança de Medicamentos Citotóxicos

A negative-pressure safety cabinet configured with enhanced filtration and dedicated exhaust for contained preparation of cytotoxic and other hazardous drug products.
  • Hazardous Drug Containment
  • Inward Operator Protection
  • Filtered Product Downflow
  • Enhanced Exhaust Filtration
Solicite um orçamento. Browse produtos

Introdução do produto

The cytotoxic cabinet uses an open-front Class II-style airflow pattern with inward capture and filtered vertical downflow, combined with dedicated exhaust and enhanced filter staging for hazardous drug work. A leak-tight stainless work zone, removable segmented tray and negative-pressure plenums reduce contamination traps. The exhaust method, filter arrangement and room installation are selected for the facility's hazardous drug handling program rather than described as one universal cabinet type.

Características-chave

Inward face airflow opposes hazardous aerosol movement toward the operator.

Filtered downflow protects prepared products and limits work-zone cross-contamination.

Additional exhaust filtration provides a secondary particulate barrier.

Negative-pressure plenums surround contaminated air paths.

A segmented work tray and spill pan support controlled cleaning after compounding.

Preocupações do produto do cliente

Hazardous drug preparation must protect the operator, product and surrounding environment while supporting controlled cleanup of spills and residues.

Aerosols can escape through the front opening during manipulation.Stable inward airflow and a defined sash height maintain the operator boundary.
Residue accumulates beneath the work surface.Segmented lift-out trays expose a stainless spill pan for cleaning.
A single filter stage offers limited redundancy.Enhanced supply and exhaust filter staging adds particulate barriers in the airflow path.
Exhaust configuration is selected without room coordination.The cabinet connection is matched to the facility exhaust and hazardous drug procedure.

Aplicações típicas

Cytotoxic drug preparationAntineoplastic compoundingHazardous sterile admixture setupOncology pharmacy support

Parâmetros técnicos

Typical configurable construction ranges for a cytotoxic drug safety cabinet are listed below.

Material principalSUS316L work-zone liner with powder-coated steel outer shell and mineral-wool insulated negative-pressure plenums
Painel de espessura40-75 mm double-skin cabinet and exhaust sections
Largura efetiva900 - 1800 mm largura de trabalho clara
Comprimento máximoUp to 2600 mm overall cabinet height
Aço enfrentando espessura1.2-1.5 mm SUS316L work-zone liner; 1.0-1.2 mm outer steel
Densidade Core100-140 kg/m³ mineral-wool plenum insulation
Condutividade térmica0.035-0.045 W/(m·K) for the mineral-wool insulation
Superfície acabadoFine-brushed or electropolished SUS316L with sealed white outer coating
Tipo conjuntoWelded negative-pressure work zone with gasketed staged-filter housings and flanged exhaust connection
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Opções disponíveis

Total exhaust or evaluated recirculating arrangementMotorized sashAdditional exhaust HEPA stageClosed-transfer compounding accessories

Planning a Cytotoxic Drug Safety Cabinet specification?

Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.