Gabinete de Segurança de Medicamentos Citotóxicos
- Hazardous Drug Containment
- Inward Operator Protection
- Filtered Product Downflow
- Enhanced Exhaust Filtration
Introdução do produto
The cytotoxic cabinet uses an open-front Class II-style airflow pattern with inward capture and filtered vertical downflow, combined with dedicated exhaust and enhanced filter staging for hazardous drug work. A leak-tight stainless work zone, removable segmented tray and negative-pressure plenums reduce contamination traps. The exhaust method, filter arrangement and room installation are selected for the facility's hazardous drug handling program rather than described as one universal cabinet type.
Características-chave
Filtered downflow protects prepared products and limits work-zone cross-contamination.
Additional exhaust filtration provides a secondary particulate barrier.
Negative-pressure plenums surround contaminated air paths.
A segmented work tray and spill pan support controlled cleaning after compounding.
Preocupações do produto do cliente
Hazardous drug preparation must protect the operator, product and surrounding environment while supporting controlled cleanup of spills and residues.
Aplicações típicas
Parâmetros técnicos
Typical configurable construction ranges for a cytotoxic drug safety cabinet are listed below.
| Material principal | SUS316L work-zone liner with powder-coated steel outer shell and mineral-wool insulated negative-pressure plenums |
|---|---|
| Painel de espessura | 40-75 mm double-skin cabinet and exhaust sections |
| Largura efetiva | 900 - 1800 mm largura de trabalho clara |
| Comprimento máximo | Up to 2600 mm overall cabinet height |
| Aço enfrentando espessura | 1.2-1.5 mm SUS316L work-zone liner; 1.0-1.2 mm outer steel |
| Densidade Core | 100-140 kg/m³ mineral-wool plenum insulation |
| Condutividade térmica | 0.035-0.045 W/(m·K) for the mineral-wool insulation |
| Superfície acabado | Fine-brushed or electropolished SUS316L with sealed white outer coating |
| Tipo conjunto | Welded negative-pressure work zone with gasketed staged-filter housings and flanged exhaust connection |
| Customização | Disponível com base na aplicação pretendida e no ambiente operacional. |
Opções disponíveis
Planning a Cytotoxic Drug Safety Cabinet specification?
Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Inglês
Alemão
Língua árabe
Francês
Língua indonésia
Japonês
Coreano
Língua malaia
Portuguêsatual
Língua russa
Espanhol
Tailandês
Língua turca
Vietnã