The cytotoxic cabinet uses an open-front Class II-style airflow pattern with inward capture and filtered vertical downflow, combined with dedicated exhaust and enhanced filter staging for hazardous drug work. A leak-tight stainless work zone, removable segmented tray and negative-pressure plenums reduce contamination traps. The exhaust method, filter arrangement and room installation are selected for the facility's hazardous drug handling program rather than described as one universal cabinet type.
Características clave
Filtered downflow protects prepared products and limits work-zone cross-contamination.
Additional exhaust filtration provides a secondary particulate barrier.
Negative-pressure plenums surround contaminated air paths.
A segmented work tray and spill pan support controlled cleaning after compounding.
Preocupaciones del producto del cliente
Hazardous drug preparation must protect the operator, product and surrounding environment while supporting controlled cleanup of spills and residues.
Aplicaciones típicas
Parámetros técnicos
Typical configurable construction ranges for a cytotoxic drug safety cabinet are listed below.
| Materiales Core | SUS316L work-zone liner with powder-coated steel outer shell and mineral-wool insulated negative-pressure plenums |
|---|---|
| Panel de espesor | 40-75 mm double-skin cabinet and exhaust sections |
| Ancho efectivo | 900 - 1800 mm Ancho de trabajo claro |
| Longitud máxima | Up to 2600 mm overall cabinet height |
| Acero frente a espesor | 1.2-1.5 mm SUS316L work-zone liner; 1.0-1.2 mm outer steel |
| Densidad Core | 100-140 kg/m³ mineral-wool plenum insulation |
| Conductividad térmica | 0.035-0.045 W/(m·K) for the mineral-wool insulation |
| Superficie acabada | Fine-brushed or electropolished SUS316L with sealed white outer coating |
| Tipo conjunto | Welded negative-pressure work zone with gasketed staged-filter housings and flanged exhaust connection |
| Customization | Disponible según la aplicación prevista y el entorno operativo. |
Opciones disponibles
Planning a Cytotoxic Drug Safety Cabinet specification?
Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Inglés
Alemán
El árabe
Francés
Idioma indonesio
El japonés
Coreano
El malayo
El portugués
El ruso
EspañolCurrent
Tailandés
El turco
El vietnamita