Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Équipement d'écoulement et de confinement laminaires

Cabinet de sécurité des médicaments cytotoxiques par

A negative-pressure safety cabinet configured with enhanced filtration and dedicated exhaust for contained preparation of cytotoxic and other hazardous drug products.
  • Hazardous Drug Containment
  • Inward Operator Protection
  • Filtered Product Downflow
  • Enhanced Exhaust Filtration
Demander un devis. Browse les produits

Introduction de produit

The cytotoxic cabinet uses an open-front Class II-style airflow pattern with inward capture and filtered vertical downflow, combined with dedicated exhaust and enhanced filter staging for hazardous drug work. A leak-tight stainless work zone, removable segmented tray and negative-pressure plenums reduce contamination traps. The exhaust method, filter arrangement and room installation are selected for the facility's hazardous drug handling program rather than described as one universal cabinet type.

Key Features

Inward face airflow opposes hazardous aerosol movement toward the operator.

Filtered downflow protects prepared products and limits work-zone cross-contamination.

Additional exhaust filtration provides a secondary particulate barrier.

Negative-pressure plenums surround contaminated air paths.

A segmented work tray and spill pan support controlled cleaning after compounding.

Préoccupations du client produit

Hazardous drug preparation must protect the operator, product and surrounding environment while supporting controlled cleanup of spills and residues.

Aerosols can escape through the front opening during manipulation.Stable inward airflow and a defined sash height maintain the operator boundary.
Residue accumulates beneath the work surface.Segmented lift-out trays expose a stainless spill pan for cleaning.
A single filter stage offers limited redundancy.Enhanced supply and exhaust filter staging adds particulate barriers in the airflow path.
Exhaust configuration is selected without room coordination.The cabinet connection is matched to the facility exhaust and hazardous drug procedure.

Les applications typiques

Cytotoxic drug preparationAntineoplastic compoundingHazardous sterile admixture setupOncology pharmacy support

Paramètres techniques

Typical configurable construction ranges for a cytotoxic drug safety cabinet are listed below.

Matériaux de baseSUS316L work-zone liner with powder-coated steel outer shell and mineral-wool insulated negative-pressure plenums
Panneau épaisseur40-75 mm double-skin cabinet and exhaust sections
Largeur effective900 - 1800 mm Largeur de travail claire
Longueur maximaleUp to 2600 mm overall cabinet height
Acier face épaisseur1.2-1.5 mm SUS316L work-zone liner; 1.0-1.2 mm outer steel
Densité Core100-140 kg/m³ mineral-wool plenum insulation
Conductivité thermique0.035-0.045 W/(m·K) for the mineral-wool insulation
surface finieFine-brushed or electropolished SUS316L with sealed white outer coating
Type jointWelded negative-pressure work zone with gasketed staged-filter housings and flanged exhaust connection
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

Total exhaust or evaluated recirculating arrangementMotorized sashAdditional exhaust HEPA stageClosed-transfer compounding accessories

Planning a Cytotoxic Drug Safety Cabinet specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe