The cytotoxic cabinet uses an open-front Class II-style airflow pattern with inward capture and filtered vertical downflow, combined with dedicated exhaust and enhanced filter staging for hazardous drug work. A leak-tight stainless work zone, removable segmented tray and negative-pressure plenums reduce contamination traps. The exhaust method, filter arrangement and room installation are selected for the facility's hazardous drug handling program rather than described as one universal cabinet type.
Key Features
Filtered downflow protects prepared products and limits work-zone cross-contamination.
Additional exhaust filtration provides a secondary particulate barrier.
Negative-pressure plenums surround contaminated air paths.
A segmented work tray and spill pan support controlled cleaning after compounding.
Préoccupations du client produit
Hazardous drug preparation must protect the operator, product and surrounding environment while supporting controlled cleanup of spills and residues.
Les applications typiques
Paramètres techniques
Typical configurable construction ranges for a cytotoxic drug safety cabinet are listed below.
| Matériaux de base | SUS316L work-zone liner with powder-coated steel outer shell and mineral-wool insulated negative-pressure plenums |
|---|---|
| Panneau épaisseur | 40-75 mm double-skin cabinet and exhaust sections |
| Largeur effective | 900 - 1800 mm Largeur de travail claire |
| Longueur maximale | Up to 2600 mm overall cabinet height |
| Acier face épaisseur | 1.2-1.5 mm SUS316L work-zone liner; 1.0-1.2 mm outer steel |
| Densité Core | 100-140 kg/m³ mineral-wool plenum insulation |
| Conductivité thermique | 0.035-0.045 W/(m·K) for the mineral-wool insulation |
| surface finie | Fine-brushed or electropolished SUS316L with sealed white outer coating |
| Type joint | Welded negative-pressure work zone with gasketed staged-filter housings and flanged exhaust connection |
| Customisation | Disponible en fonction de l'application prévue et de l'environnement d'exploitation. |
Options disponibles
Planning a Cytotoxic Drug Safety Cabinet specification?
Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Anglais
Allemand
Arabe
FrançaisCurrent
Indonésien
Japonais
Coréen
Le malais
Le portugais
russe
espagnol
Thaïlandais
Le turc
Le vietnamien