Ihr One-Stop - Lieferant für Reinraumausrüstung und Essentials für aseptische EinrichtungenInternationale Projektunterstützung
Open mobile navigationClose mobile navigation
Startseite / Produkte / Laminar Flow und Containment Equipment / Cytotoxic Drug Safety Cabinet
Laminar Flow und Containment Equipment

Cytotoxic Drug Safety Cabinet

A negative-pressure safety cabinet configured with enhanced filtration and dedicated exhaust for contained preparation of cytotoxic and other hazardous drug products.
  • Hazardous Drug Containment
  • Inward Operator Protection
  • Filtered Product Downflow
  • Enhanced Exhaust Filtration

Produkteinführung

The cytotoxic cabinet uses an open-front Class II-style airflow pattern with inward capture and filtered vertical downflow, combined with dedicated exhaust and enhanced filter staging for hazardous drug work. A leak-tight stainless work zone, removable segmented tray and negative-pressure plenums reduce contamination traps. The exhaust method, filter arrangement and room installation are selected for the facility's hazardous drug handling program rather than described as one universal cabinet type.

Key Features

Inward face airflow opposes hazardous aerosol movement toward the operator.

Filtered downflow protects prepared products and limits work-zone cross-contamination.

Additional exhaust filtration provides a secondary particulate barrier.

Negative-pressure plenums surround contaminated air paths.

A segmented work tray and spill pan support controlled cleaning after compounding.

Kunden Produktbedenken

Hazardous drug preparation must protect the operator, product and surrounding environment while supporting controlled cleanup of spills and residues.

Aerosols can escape through the front opening during manipulation.Stable inward airflow and a defined sash height maintain the operator boundary.
Residue accumulates beneath the work surface.Segmented lift-out trays expose a stainless spill pan for cleaning.
A single filter stage offers limited redundancy.Enhanced supply and exhaust filter staging adds particulate barriers in the airflow path.
Exhaust configuration is selected without room coordination.The cabinet connection is matched to the facility exhaust and hazardous drug procedure.

Typische Anwendungen

Cytotoxic drug preparationAntineoplastic compoundingHazardous sterile admixture setupOncology pharmacy support

Technische Parameter

Typical configurable construction ranges for a cytotoxic drug safety cabinet are listed below.

Core MaterialSUS316L work-zone liner with powder-coated steel outer shell and mineral-wool insulated negative-pressure plenums
Panel Dicke40-75 mm double-skin cabinet and exhaust sections
Effektive Breite900 - 1800 mm klare Arbeitsbreite
Maximale LängeUp to 2600 mm overall cabinet height
Stahl facing Dicke1.2-1.5 mm SUS316L work-zone liner; 1.0-1.2 mm outer steel
Kerndichte100-140 kg/m³ mineral-wool plenum insulation
Thermische Leitfähigkeit0.035-0.045 W/(m·K) for the mineral-wool insulation
Oberfläche FinishFine-brushed or electropolished SUS316L with sealed white outer coating
Gemeinsamer TypWelded negative-pressure work zone with gasketed staged-filter housings and flanged exhaust connection
CustomisierungVerfügbar je nach beabsichtigter Anwendung und Betriebsumgebung.

Verfügbare Optionen

Total exhaust or evaluated recirculating arrangementMotorized sashAdditional exhaust HEPA stageClosed-transfer compounding accessories

Planning a Cytotoxic Drug Safety Cabinet specification?

Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.