Cytotoxic Drug Safety Cabinet
- Hazardous Drug Containment
- Inward Operator Protection
- Filtered Product Downflow
- Enhanced Exhaust Filtration
Produkteinführung
The cytotoxic cabinet uses an open-front Class II-style airflow pattern with inward capture and filtered vertical downflow, combined with dedicated exhaust and enhanced filter staging for hazardous drug work. A leak-tight stainless work zone, removable segmented tray and negative-pressure plenums reduce contamination traps. The exhaust method, filter arrangement and room installation are selected for the facility's hazardous drug handling program rather than described as one universal cabinet type.
Key Features
Filtered downflow protects prepared products and limits work-zone cross-contamination.
Additional exhaust filtration provides a secondary particulate barrier.
Negative-pressure plenums surround contaminated air paths.
A segmented work tray and spill pan support controlled cleaning after compounding.
Kunden Produktbedenken
Hazardous drug preparation must protect the operator, product and surrounding environment while supporting controlled cleanup of spills and residues.
Typische Anwendungen
Technische Parameter
Typical configurable construction ranges for a cytotoxic drug safety cabinet are listed below.
| Core Material | SUS316L work-zone liner with powder-coated steel outer shell and mineral-wool insulated negative-pressure plenums |
|---|---|
| Panel Dicke | 40-75 mm double-skin cabinet and exhaust sections |
| Effektive Breite | 900 - 1800 mm klare Arbeitsbreite |
| Maximale Länge | Up to 2600 mm overall cabinet height |
| Stahl facing Dicke | 1.2-1.5 mm SUS316L work-zone liner; 1.0-1.2 mm outer steel |
| Kerndichte | 100-140 kg/m³ mineral-wool plenum insulation |
| Thermische Leitfähigkeit | 0.035-0.045 W/(m·K) for the mineral-wool insulation |
| Oberfläche Finish | Fine-brushed or electropolished SUS316L with sealed white outer coating |
| Gemeinsamer Typ | Welded negative-pressure work zone with gasketed staged-filter housings and flanged exhaust connection |
| Customisierung | Verfügbar je nach beabsichtigter Anwendung und Betriebsumgebung. |
Verfügbare Optionen
Planning a Cytotoxic Drug Safety Cabinet specification?
Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.