Pembekal Satu Henti Anda untuk Peralatan Bilik Bersih dan Kemudahan AseptikSokongan Projek Antarabangsa
Open mobile navigationClose mobile navigation
Laman Utama / Produk / Aliran Laminar dan Peralatan Pengekangan / Cytotoxic Drug Safety Cabinet
Aliran Laminar dan Peralatan Pengekangan

Kabinet Keselamatan Dadah Sitotoksik

A negative-pressure safety cabinet configured with enhanced filtration and dedicated exhaust for contained preparation of cytotoxic and other hazardous drug products.
  • Hazardous Drug Containment
  • Inward Operator Protection
  • Filtered Product Downflow
  • Enhanced Exhaust Filtration
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

The cytotoxic cabinet uses an open-front Class II-style airflow pattern with inward capture and filtered vertical downflow, combined with dedicated exhaust and enhanced filter staging for hazardous drug work. A leak-tight stainless work zone, removable segmented tray and negative-pressure plenums reduce contamination traps. The exhaust method, filter arrangement and room installation are selected for the facility's hazardous drug handling program rather than described as one universal cabinet type.

Ciri-ciri Utama

Inward face airflow opposes hazardous aerosol movement toward the operator.

Filtered downflow protects prepared products and limits work-zone cross-contamination.

Additional exhaust filtration provides a secondary particulate barrier.

Negative-pressure plenums surround contaminated air paths.

A segmented work tray and spill pan support controlled cleaning after compounding.

Kebimbangan Produk Pelanggan

Hazardous drug preparation must protect the operator, product and surrounding environment while supporting controlled cleanup of spills and residues.

Aerosols can escape through the front opening during manipulation.Stable inward airflow and a defined sash height maintain the operator boundary.
Residue accumulates beneath the work surface.Segmented lift-out trays expose a stainless spill pan for cleaning.
A single filter stage offers limited redundancy.Enhanced supply and exhaust filter staging adds particulate barriers in the airflow path.
Exhaust configuration is selected without room coordination.The cabinet connection is matched to the facility exhaust and hazardous drug procedure.

Permohonan yang biasa

Cytotoxic drug preparationAntineoplastic compoundingHazardous sterile admixture setupOncology pharmacy support

Parameter teknikal

Typical configurable construction ranges for a cytotoxic drug safety cabinet are listed below.

Bahan TerasSUS316L work-zone liner with powder-coated steel outer shell and mineral-wool insulated negative-pressure plenums
Ketebalan Panel40-75 mm double-skin cabinet and exhaust sections
Lebar berkesan900-1800 mm lebar kerja yang jelas
Panjang maksimumUp to 2600 mm overall cabinet height
Keluli Menghadapi Ketebalan1.2-1.5 mm SUS316L work-zone liner; 1.0-1.2 mm outer steel
Ketumpatan teras100-140 kg/m³ mineral-wool plenum insulation
Kekonduksian Terma0.035-0.045 W/(m·K) for the mineral-wool insulation
Kemasan permukaanFine-brushed or electropolished SUS316L with sealed white outer coating
Jenis BersatuWelded negative-pressure work zone with gasketed staged-filter housings and flanged exhaust connection
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Pilihan yang boleh didapati

Total exhaust or evaluated recirculating arrangementMotorized sashAdditional exhaust HEPA stageClosed-transfer compounding accessories

Planning a Cytotoxic Drug Safety Cabinet specification?

Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Berbincang dengan pasukan kami
Email Kami WhatsApp WeChat

Laman Utama

Produk

Berita

Tentang Kami

Hubungi Kami