Umidificador de troca de vapor limpo
- Separated Plant-Steam Circuit
- 316 Stainless Heat Exchanger
- Modulating Clean-Steam Output
- Sanitary Drainable Construction
Introdução do produto
The clean steam exchange humidifier transfers heat from pressurized facility steam through a stainless heat exchanger into potable, reverse-osmosis or deionized make-up water. Boiler additives remain isolated from the atmospheric steam delivered to the air-handling system. A drainable vessel, modulating steam valve, level control and stainless dispersion assembly create a serviceable package for processes that require controlled humidity without introducing boiler-treatment carryover.
Características-chave
The 316 stainless heat exchanger provides a durable corrosion-resistant heat-transfer surface, while the vessel and remaining packaged components use stainless-steel construction suited to their service.
Modulating steam admission follows the humidity signal without cycling electric heating elements.
Accessible vessel connections, removable separator components and automatic drain functions simplify scale removal and sanitation routines.
Preocupações do produto do cliente
Critical facilities often have abundant plant steam but cannot permit boiler-treatment chemicals or entrained condensate to enter the cleanroom supply air.
Aplicações típicas
Parâmetros técnicos
Typical construction ranges for a packaged steam-exchange humidifier serving cleanroom air systems are shown below.
| Material principal | 316 stainless steel heat exchanger with a stainless-steel vessel, separator and packaged piping |
|---|---|
| Painel de espessura | 1.5-3.0 mm stainless vessel shell and fabricated support thickness |
| Largura efetiva | 700-1600 mm typical skid width according to steam capacity |
| Comprimento máximo | Up to 1500 mm overall cabinet/skid length for the largest listed packaged capacity |
| Aço enfrentando espessura | 1.2-2.0 mm stainless guard, drip tray or optional enclosure sheet |
| Densidade Core | Approximately 7900-8000 kg/m³ for austenitic stainless wetted components |
| Condutividade térmica | Approximately 14-16 W/(m·K) for the 316 stainless heat exchanger at room temperature |
| Superfície acabado | Pickled and passivated stainless steel with smooth drainable wetted surfaces |
| Tipo conjunto | Sanitary clamp or flanged steam connections with welded stainless piping and gasketed vessel closures |
| Customização | Disponível com base na aplicação pretendida e no ambiente operacional. |
Opções disponíveis
Planning a Clean Steam Exchange Humidifier specification?
Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Inglês
Alemão
Língua árabe
Francês
Língua indonésia
Japonês
Coreano
Língua malaia
Portuguêsatual
Língua russa
Espanhol
Tailandês
Língua turca
Vietnã