نظيف البخار تبادل المرطب
- Separated Plant-Steam Circuit
- 316 Stainless Heat Exchanger
- Modulating Clean-Steam Output
- Sanitary Drainable Construction
مقدمة المنتج
The clean steam exchange humidifier transfers heat from pressurized facility steam through a stainless heat exchanger into potable, reverse-osmosis or deionized make-up water. Boiler additives remain isolated from the atmospheric steam delivered to the air-handling system. A drainable vessel, modulating steam valve, level control and stainless dispersion assembly create a serviceable package for processes that require controlled humidity without introducing boiler-treatment carryover.
الخصائص الرئيسية
The 316 stainless heat exchanger provides a durable corrosion-resistant heat-transfer surface, while the vessel and remaining packaged components use stainless-steel construction suited to their service.
Modulating steam admission follows the humidity signal without cycling electric heating elements.
Accessible vessel connections, removable separator components and automatic drain functions simplify scale removal and sanitation routines.
مخاوف المنتج للعملاء
Critical facilities often have abundant plant steam but cannot permit boiler-treatment chemicals or entrained condensate to enter the cleanroom supply air.
تطبيقات نموذجية
المعلمات الفنية
Typical construction ranges for a packaged steam-exchange humidifier serving cleanroom air systems are shown below.
| المواد الأساسية | 316 stainless steel heat exchanger with a stainless-steel vessel, separator and packaged piping |
|---|---|
| سمك اللوحة | 1.5-3.0 mm stainless vessel shell and fabricated support thickness |
| العرض الفعال | 700-1600 mm typical skid width according to steam capacity |
| الحد الأقصى الطول | Up to 1500 mm overall cabinet/skid length for the largest listed packaged capacity |
| الصلب يواجه سمك | 1.2-2.0 mm stainless guard, drip tray or optional enclosure sheet |
| الكثافة الأساسية | Approximately 7900-8000 kg/m³ for austenitic stainless wetted components |
| الموصلية الحرارية | Approximately 14-16 W/(m·K) for the 316 stainless heat exchanger at room temperature |
| إنهاء السطح | Pickled and passivated stainless steel with smooth drainable wetted surfaces |
| نوع المشترك | Sanitary clamp or flanged steam connections with welded stainless piping and gasketed vessel closures |
| التخصيص | متوفر على أساس التطبيق المقصود وبيئة التشغيل. |
الخيارات المتاحة
Planning a Clean Steam Exchange Humidifier specification?