Humidificador de intercambio de vapor limpio
- Separated Plant-Steam Circuit
- 316 Stainless Heat Exchanger
- Modulating Clean-Steam Output
- Sanitary Drainable Construction
Introducción del producto
The clean steam exchange humidifier transfers heat from pressurized facility steam through a stainless heat exchanger into potable, reverse-osmosis or deionized make-up water. Boiler additives remain isolated from the atmospheric steam delivered to the air-handling system. A drainable vessel, modulating steam valve, level control and stainless dispersion assembly create a serviceable package for processes that require controlled humidity without introducing boiler-treatment carryover.
Características clave
The 316 stainless heat exchanger provides a durable corrosion-resistant heat-transfer surface, while the vessel and remaining packaged components use stainless-steel construction suited to their service.
Modulating steam admission follows the humidity signal without cycling electric heating elements.
Accessible vessel connections, removable separator components and automatic drain functions simplify scale removal and sanitation routines.
Preocupaciones del producto del cliente
Critical facilities often have abundant plant steam but cannot permit boiler-treatment chemicals or entrained condensate to enter the cleanroom supply air.
Aplicaciones típicas
Parámetros técnicos
Typical construction ranges for a packaged steam-exchange humidifier serving cleanroom air systems are shown below.
| Materiales Core | 316 stainless steel heat exchanger with a stainless-steel vessel, separator and packaged piping |
|---|---|
| Panel de espesor | 1.5-3.0 mm stainless vessel shell and fabricated support thickness |
| Ancho efectivo | 700-1600 mm typical skid width according to steam capacity |
| Longitud máxima | Up to 1500 mm overall cabinet/skid length for the largest listed packaged capacity |
| Acero frente a espesor | 1.2-2.0 mm stainless guard, drip tray or optional enclosure sheet |
| Densidad Core | Approximately 7900-8000 kg/m³ for austenitic stainless wetted components |
| Conductividad térmica | Approximately 14-16 W/(m·K) for the 316 stainless heat exchanger at room temperature |
| Superficie acabada | Pickled and passivated stainless steel with smooth drainable wetted surfaces |
| Tipo conjunto | Sanitary clamp or flanged steam connections with welded stainless piping and gasketed vessel closures |
| Customization | Disponible según la aplicación prevista y el entorno operativo. |
Opciones disponibles
Planning a Clean Steam Exchange Humidifier specification?
Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.