Seu fornecedor único para equipamentos de sala limpa e instalações assépticas essenciaisApoio Internacional a Projetos
Open mobile navigationClose mobile navigation
Controle de sala limpa e sistemas de monitoramento ambiental

Sensor de dióxido de carbono

A wall-mounted NDIR sensor that measures carbon dioxide concentration for occupancy-related ventilation and cleanroom environmental trending.
  • NDIR CO₂ Measurement
  • Long-Term Optical Stability
  • Ventilation Demand Signal
  • Selectable 0-10 V, 4-20 mA or Fieldbus Output
Solicite um orçamento. Browse produtos

Introdução do produto

The carbon dioxide sensor uses non-dispersive infrared absorption to measure CO₂ without consuming a reactive sensing material. Room air diffuses through protected openings into the optical chamber, where wavelength-selective measurement separates carbon dioxide absorption from the reference signal. Temperature compensation and baseline-management options support stable indoor operation. Selectable voltage, current or network outputs let ventilation controls, environmental monitoring and room displays use the same measured concentration.

Características-chave

NDIR optical measurement is selective to carbon dioxide and does not consume electrolyte.

A dual-channel or reference-compensated design reduces long-term light-source drift.

Ventilated wall housing samples occupied-zone air while protecting the optical chamber.

Configurable analog and network outputs support both HVAC control and monitoring.

Preocupações do produto do cliente

CO₂ measurements are most useful when the sensor sees representative room air and its baseline behavior matches the occupancy pattern.

A sensor near a door or supply diffuser responds to transient air instead of the occupied zone.A stable wall location away from direct drafts provides a more representative room sample.
Automatic baseline correction is unsuitable for continuously occupied spaces.Selectable baseline strategy allows fixed or manually referenced calibration where CO₂ never falls to outdoor levels.
Dust or cleaning spray enters the optical path.Protected diffusion vents and an easy-wipe enclosure reduce direct contamination.
Ventilation controls and monitoring use separate sensors that disagree.Multiple outputs distribute one measured value to both systems.

Aplicações típicas

Occupied cleanroom ventilationLaboratory room monitoringControlled production suitesClean corridors and support areas

Parâmetros técnicos

Typical materials and dimensions for a wall-mounted NDIR carbon dioxide sensor are listed below.

Material principalNDIR optical chamber with infrared source and detector in flame-retardant polycarbonate housing
Painel de espessura30-50 mm sensor depth
Largura efetiva90-130 mm housing width
Comprimento máximoUp to 150 mm housing height
Aço enfrentando espessura0 mm; non-metallic wall enclosure
Densidade Core1180-1220 kg/m³ for polycarbonate housing material
Condutividade térmica0.19-0.22 W/(m·K) for polycarbonate enclosure
Superfície acabadoSmooth white housing with black display window and green status indicator
Tipo conjuntoRear wall-mount base with protected diffusion vents and pluggable signal terminal
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Opções disponíveis

Display or blank faceVoltage or 4-20 mA outputModbus or BACnet communicationSelectable baseline correction

Planning a Carbon Dioxide Sensor specification?

Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Fale com a nossa equipe
Email-nos O WhatsApp WeChat

Início

Produtos

Notícias

Sobre nós

Contato