Ihr One-Stop - Lieferant für Reinraumausrüstung und Essentials für aseptische EinrichtungenInternationale Projektunterstützung
Open mobile navigationClose mobile navigation
Reinraumsteuerung und Umweltüberwachungssysteme

Kohlendioxid-Sensor

A wall-mounted NDIR sensor that measures carbon dioxide concentration for occupancy-related ventilation and cleanroom environmental trending.
  • NDIR CO₂ Measurement
  • Long-Term Optical Stability
  • Ventilation Demand Signal
  • Selectable 0-10 V, 4-20 mA or Fieldbus Output

Produkteinführung

The carbon dioxide sensor uses non-dispersive infrared absorption to measure CO₂ without consuming a reactive sensing material. Room air diffuses through protected openings into the optical chamber, where wavelength-selective measurement separates carbon dioxide absorption from the reference signal. Temperature compensation and baseline-management options support stable indoor operation. Selectable voltage, current or network outputs let ventilation controls, environmental monitoring and room displays use the same measured concentration.

Key Features

NDIR optical measurement is selective to carbon dioxide and does not consume electrolyte.

A dual-channel or reference-compensated design reduces long-term light-source drift.

Ventilated wall housing samples occupied-zone air while protecting the optical chamber.

Configurable analog and network outputs support both HVAC control and monitoring.

Kunden Produktbedenken

CO₂ measurements are most useful when the sensor sees representative room air and its baseline behavior matches the occupancy pattern.

A sensor near a door or supply diffuser responds to transient air instead of the occupied zone.A stable wall location away from direct drafts provides a more representative room sample.
Automatic baseline correction is unsuitable for continuously occupied spaces.Selectable baseline strategy allows fixed or manually referenced calibration where CO₂ never falls to outdoor levels.
Dust or cleaning spray enters the optical path.Protected diffusion vents and an easy-wipe enclosure reduce direct contamination.
Ventilation controls and monitoring use separate sensors that disagree.Multiple outputs distribute one measured value to both systems.

Typische Anwendungen

Occupied cleanroom ventilationLaboratory room monitoringControlled production suitesClean corridors and support areas

Technische Parameter

Typical materials and dimensions for a wall-mounted NDIR carbon dioxide sensor are listed below.

Core MaterialNDIR optical chamber with infrared source and detector in flame-retardant polycarbonate housing
Panel Dicke30-50 mm sensor depth
Effektive Breite90-130 mm housing width
Maximale LängeUp to 150 mm housing height
Stahl facing Dicke0 mm; non-metallic wall enclosure
Kerndichte1180-1220 kg/m³ for polycarbonate housing material
Thermische Leitfähigkeit0.19-0.22 W/(m·K) for polycarbonate enclosure
Oberfläche FinishSmooth white housing with black display window and green status indicator
Gemeinsamer TypRear wall-mount base with protected diffusion vents and pluggable signal terminal
CustomisierungVerfügbar je nach beabsichtigter Anwendung und Betriebsumgebung.

Verfügbare Optionen

Display or blank faceVoltage or 4-20 mA outputModbus or BACnet communicationSelectable baseline correction

Planning a Carbon Dioxide Sensor specification?

Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.

Sprechen Sie mit unserem Team