Z Air-cooled chillers
- No Cooling Tower Required
- Outdoor Heat Rejection
- Staged or Variable Capacity
- Optional Integrated Hydronics
Introdução do produto
The air-cooled chiller circulates refrigerant between one or more compressors, a liquid evaporator and outdoor finned condenser coils. Axial fans move ambient air through the condenser, eliminating the cooling tower, condenser-water pump and water-treatment loop associated with a water-cooled plant. Scroll compressors suit smaller and modular duties, while screw compressors serve larger capacities. Multiple refrigerant circuits, fan staging and optional variable-speed control improve part-load response and allow the chiller to follow changing cleanroom demand.
Características-chave
Independent refrigerant circuits provide staged capacity and reduce the impact of a single circuit shutdown.
Variable condenser fans control head pressure and reduce fan power during mild weather.
Factory hydronic options can combine pumps, expansion vessel and buffer volume on one outdoor base.
Preocupações do produto do cliente
Air-cooled chillers are simple to site, but their capacity, noise and condensing pressure change with outdoor temperature and airflow conditions.
Aplicações típicas
Parâmetros técnicos
Representative construction and cold-surface insulation data for an outdoor air-cooled chiller are listed below.
| Material principal | Closed-cell NBR/PVC elastomeric foam on the evaporator and refrigerant suction piping |
|---|---|
| Painel de espessura | 1.0–2.0 mm removable equipment enclosure panels |
| Largura efetiva | 1000–2500 mm nominal unit width |
| Comprimento máximo | Up to 12000 mm for multi-circuit V-bank condenser arrangement |
| Aço enfrentando espessura | 1.0–2.0 mm galvanized structural and service panels |
| Densidade Core | 48–96 kg/m³ NBR/PVC elastomeric insulation |
| Condutividade térmica | 0.0353 W/(m·K) at 24°C for the NBR/PVC elastomeric insulation |
| Superfície acabado | Outdoor polyester powder-coated galvanized steel with aluminum finned condenser coils |
| Tipo conjunto | Welded structural base with bolted coil frames and removable gasketed service panels |
| Customização | Disponível com base na aplicação pretendida e no ambiente operacional. |
Opções disponíveis
Planning a Air-Cooled Chiller specification?
Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.