Z Air-cooled chillers

An outdoor liquid chiller that rejects heat directly to ambient air and supplies chilled water to cleanroom coils without a cooling tower.
  • No Cooling Tower Required
  • Outdoor Heat Rejection
  • Staged or Variable Capacity
  • Optional Integrated Hydronics
Solicite um orçamento. Browse produtos

Introdução do produto

The air-cooled chiller circulates refrigerant between one or more compressors, a liquid evaporator and outdoor finned condenser coils. Axial fans move ambient air through the condenser, eliminating the cooling tower, condenser-water pump and water-treatment loop associated with a water-cooled plant. Scroll compressors suit smaller and modular duties, while screw compressors serve larger capacities. Multiple refrigerant circuits, fan staging and optional variable-speed control improve part-load response and allow the chiller to follow changing cleanroom demand.

Características-chave

Ambient-air heat rejection removes the need for a separate cooling-tower water system.

Independent refrigerant circuits provide staged capacity and reduce the impact of a single circuit shutdown.

Variable condenser fans control head pressure and reduce fan power during mild weather.

Factory hydronic options can combine pumps, expansion vessel and buffer volume on one outdoor base.

Preocupações do produto do cliente

Air-cooled chillers are simple to site, but their capacity, noise and condensing pressure change with outdoor temperature and airflow conditions.

Hot recirculated discharge air reduces chiller capacity on a crowded roof.Adequate coil clearance and discharge orientation prevent short-circuiting of condenser air.
A large fixed compressor cycles repeatedly during low cleanroom load.Multiple circuits or variable-speed compression provide smaller capacity steps.
Low chilled-water volume causes rapid temperature swings and compressor cycling.A correctly sized buffer tank or minimum system volume stabilizes the hydronic loop.
Condenser noise reaches nearby occupied areas.Low-speed fan selection, compressor attenuation and night sound modes address acoustic limits.

Aplicações típicas

Cleanroom chilled-water plantsPharmaceutical process coolingLaboratory HVAC systemsProdução de dispositivos médicosIndustrial temperature-control loops

Parâmetros técnicos

Representative construction and cold-surface insulation data for an outdoor air-cooled chiller are listed below.

Material principalClosed-cell NBR/PVC elastomeric foam on the evaporator and refrigerant suction piping
Painel de espessura1.0–2.0 mm removable equipment enclosure panels
Largura efetiva1000–2500 mm nominal unit width
Comprimento máximoUp to 12000 mm for multi-circuit V-bank condenser arrangement
Aço enfrentando espessura1.0–2.0 mm galvanized structural and service panels
Densidade Core48–96 kg/m³ NBR/PVC elastomeric insulation
Condutividade térmica0.0353 W/(m·K) at 24°C for the NBR/PVC elastomeric insulation
Superfície acabadoOutdoor polyester powder-coated galvanized steel with aluminum finned condenser coils
Tipo conjuntoWelded structural base with bolted coil frames and removable gasketed service panels
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Opções disponíveis

Scroll or screw compressor platformMicrochannel or aluminum-copper condenser coilIntegrated single or twin hydronic pumpsLow-ambient, low-noise and free-cooling packages