Hava Soğutmalı Soğutucu

An outdoor liquid chiller that rejects heat directly to ambient air and supplies chilled water to cleanroom coils without a cooling tower.
  • No Cooling Tower Required
  • Outdoor Heat Rejection
  • Staged or Variable Capacity
  • Optional Integrated Hydronics
Alıntı isteği Browse ürünleri

Ürün tanıtımı

The air-cooled chiller circulates refrigerant between one or more compressors, a liquid evaporator and outdoor finned condenser coils. Axial fans move ambient air through the condenser, eliminating the cooling tower, condenser-water pump and water-treatment loop associated with a water-cooled plant. Scroll compressors suit smaller and modular duties, while screw compressors serve larger capacities. Multiple refrigerant circuits, fan staging and optional variable-speed control improve part-load response and allow the chiller to follow changing cleanroom demand.

Ana Özellikler

Ambient-air heat rejection removes the need for a separate cooling-tower water system.

Independent refrigerant circuits provide staged capacity and reduce the impact of a single circuit shutdown.

Variable condenser fans control head pressure and reduce fan power during mild weather.

Factory hydronic options can combine pumps, expansion vessel and buffer volume on one outdoor base.

Müşteri Ürün Sorunları

Air-cooled chillers are simple to site, but their capacity, noise and condensing pressure change with outdoor temperature and airflow conditions.

Hot recirculated discharge air reduces chiller capacity on a crowded roof.Adequate coil clearance and discharge orientation prevent short-circuiting of condenser air.
A large fixed compressor cycles repeatedly during low cleanroom load.Multiple circuits or variable-speed compression provide smaller capacity steps.
Low chilled-water volume causes rapid temperature swings and compressor cycling.A correctly sized buffer tank or minimum system volume stabilizes the hydronic loop.
Condenser noise reaches nearby occupied areas.Low-speed fan selection, compressor attenuation and night sound modes address acoustic limits.

Tipik uygulamalar

Cleanroom chilled-water plantsPharmaceutical process coolingLaboratory HVAC systemsTıbbi cihaz üretimiIndustrial temperature-control loops

Teknik parametreler

Representative construction and cold-surface insulation data for an outdoor air-cooled chiller are listed below.

Temel malzemelerClosed-cell NBR/PVC elastomeric foam on the evaporator and refrigerant suction piping
Panel kalınlığı1.0–2.0 mm removable equipment enclosure panels
Effective Width (Etkili Genişlik)1000–2500 mm nominal unit width
Maksimum uzunlukUp to 12000 mm for multi-circuit V-bank condenser arrangement
Çelik yüz yüze kalınlığı1.0–2.0 mm galvanized structural and service panels
Core Density (Çekirdek Yoğunluğu)48–96 kg/m³ NBR/PVC elastomeric insulation
Termal İletkenlik0.0353 W/(m·K) at 24°C for the NBR/PVC elastomeric insulation
Yüzey bitirmeOutdoor polyester powder-coated galvanized steel with aluminum finned condenser coils
Ortak tipWelded structural base with bolted coil frames and removable gasketed service panels
Customization (Özelleşme)Kullanılan uygulama ve çalışma ortamına göre kullanılabilir.

Mevcut Seçenekler

Scroll or screw compressor platformMicrochannel or aluminum-copper condenser coilIntegrated single or twin hydronic pumpsLow-ambient, low-noise and free-cooling packages