موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
معدات تهوية وتكييف ومعالجة الهواء في الغرف النظيفة

تبريد الهواء مبرد

An outdoor liquid chiller that rejects heat directly to ambient air and supplies chilled water to cleanroom coils without a cooling tower.
  • No Cooling Tower Required
  • Outdoor Heat Rejection
  • Staged or Variable Capacity
  • Optional Integrated Hydronics
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The air-cooled chiller circulates refrigerant between one or more compressors, a liquid evaporator and outdoor finned condenser coils. Axial fans move ambient air through the condenser, eliminating the cooling tower, condenser-water pump and water-treatment loop associated with a water-cooled plant. Scroll compressors suit smaller and modular duties, while screw compressors serve larger capacities. Multiple refrigerant circuits, fan staging and optional variable-speed control improve part-load response and allow the chiller to follow changing cleanroom demand.

الخصائص الرئيسية

Ambient-air heat rejection removes the need for a separate cooling-tower water system.

Independent refrigerant circuits provide staged capacity and reduce the impact of a single circuit shutdown.

Variable condenser fans control head pressure and reduce fan power during mild weather.

Factory hydronic options can combine pumps, expansion vessel and buffer volume on one outdoor base.

مخاوف المنتج للعملاء

Air-cooled chillers are simple to site, but their capacity, noise and condensing pressure change with outdoor temperature and airflow conditions.

Hot recirculated discharge air reduces chiller capacity on a crowded roof.Adequate coil clearance and discharge orientation prevent short-circuiting of condenser air.
A large fixed compressor cycles repeatedly during low cleanroom load.Multiple circuits or variable-speed compression provide smaller capacity steps.
Low chilled-water volume causes rapid temperature swings and compressor cycling.A correctly sized buffer tank or minimum system volume stabilizes the hydronic loop.
Condenser noise reaches nearby occupied areas.Low-speed fan selection, compressor attenuation and night sound modes address acoustic limits.

تطبيقات نموذجية

Cleanroom chilled-water plantsPharmaceutical process coolingLaboratory HVAC systemsإنتاج الأجهزة الطبيةIndustrial temperature-control loops

المعلمات الفنية

Representative construction and cold-surface insulation data for an outdoor air-cooled chiller are listed below.

المواد الأساسيةClosed-cell NBR/PVC elastomeric foam on the evaporator and refrigerant suction piping
سمك اللوحة1.0–2.0 mm removable equipment enclosure panels
العرض الفعال1000–2500 mm nominal unit width
الحد الأقصى الطولUp to 12000 mm for multi-circuit V-bank condenser arrangement
الصلب يواجه سمك1.0–2.0 mm galvanized structural and service panels
الكثافة الأساسية48–96 kg/m³ NBR/PVC elastomeric insulation
الموصلية الحرارية0.0353 W/(m·K) at 24°C for the NBR/PVC elastomeric insulation
إنهاء السطحOutdoor polyester powder-coated galvanized steel with aluminum finned condenser coils
نوع المشتركWelded structural base with bolted coil frames and removable gasketed service panels
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

Scroll or screw compressor platformMicrochannel or aluminum-copper condenser coilIntegrated single or twin hydronic pumpsLow-ambient, low-noise and free-cooling packages

Planning a Air-Cooled Chiller specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat

الرئيسية

المنتجات

الأخبار

من نحن

اتصل بنا