Air - Cooled Chiller

An outdoor liquid chiller that rejects heat directly to ambient air and supplies chilled water to cleanroom coils without a cooling tower.
  • No Cooling Tower Required
  • Outdoor Heat Rejection
  • Staged or Variable Capacity
  • Optional Integrated Hydronics
견적 요청 제품 찾아보기

상품 소개

The air-cooled chiller circulates refrigerant between one or more compressors, a liquid evaporator and outdoor finned condenser coils. Axial fans move ambient air through the condenser, eliminating the cooling tower, condenser-water pump and water-treatment loop associated with a water-cooled plant. Scroll compressors suit smaller and modular duties, while screw compressors serve larger capacities. Multiple refrigerant circuits, fan staging and optional variable-speed control improve part-load response and allow the chiller to follow changing cleanroom demand.

주요 기능

Ambient-air heat rejection removes the need for a separate cooling-tower water system.

Independent refrigerant circuits provide staged capacity and reduce the impact of a single circuit shutdown.

Variable condenser fans control head pressure and reduce fan power during mild weather.

Factory hydronic options can combine pumps, expansion vessel and buffer volume on one outdoor base.

고객 제품 관심사

Air-cooled chillers are simple to site, but their capacity, noise and condensing pressure change with outdoor temperature and airflow conditions.

Hot recirculated discharge air reduces chiller capacity on a crowded roof.Adequate coil clearance and discharge orientation prevent short-circuiting of condenser air.
A large fixed compressor cycles repeatedly during low cleanroom load.Multiple circuits or variable-speed compression provide smaller capacity steps.
Low chilled-water volume causes rapid temperature swings and compressor cycling.A correctly sized buffer tank or minimum system volume stabilizes the hydronic loop.
Condenser noise reaches nearby occupied areas.Low-speed fan selection, compressor attenuation and night sound modes address acoustic limits.

일반적인 응용 프로그램

Cleanroom chilled-water plantsPharmaceutical process coolingLaboratory HVAC systems의료기기 제조Industrial temperature-control loops

기술 매개변수

Representative construction and cold-surface insulation data for an outdoor air-cooled chiller are listed below.

핵심 재료Closed-cell NBR/PVC elastomeric foam on the evaporator and refrigerant suction piping
패널 두께1.0–2.0 mm removable equipment enclosure panels
유효 폭1000–2500 mm nominal unit width
최대 길이Up to 12000 mm for multi-circuit V-bank condenser arrangement
강철 면면 두께1.0–2.0 mm galvanized structural and service panels
코어 밀도48–96 kg/m³ NBR/PVC elastomeric insulation
열전도도 (Thermal Conductivity)0.0353 W/(m·K) at 24°C for the NBR/PVC elastomeric insulation
표면 마무리Outdoor polyester powder-coated galvanized steel with aluminum finned condenser coils
접합 유형Welded structural base with bolted coil frames and removable gasketed service panels
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

사용 가능한 옵션

Scroll or screw compressor platformMicrochannel or aluminum-copper condenser coilIntegrated single or twin hydronic pumpsLow-ambient, low-noise and free-cooling packages