Rapid Transfer Port
- Alpha-Beta Double Door
- Sealed Docking Interface
- Mechanical Interlock
- Reusable Transfer Container
Product Introduction
The rapid transfer port system combines a fixed alpha flange on the barrier with a mating beta container. When docked and locked, the two doors open together so their previously exposed faces remain sealed away from the transfer path. A defined rotational lock, elastomer seal and status indication guide repeatable connection and prevent opening when the container is not correctly engaged.
Key Features
Mechanical locking sequence prevents opening before the container is fully docked.
Replaceable elastomer sealing rings maintain a cleanable, pressure-resistant interface.
Reusable stainless beta containers support tools, components and waste transfers.
Customer Product Concerns
Opening a conventional hatch connects the surrounding room directly to the isolator chamber and exposes door surfaces to the transfer route.
Typical Applications
Technical Parameters
Typical construction values for a pharmaceutical rapid transfer port system are listed below.
| Core Material | 316L stainless steel alpha flange and beta container with silicone or EPDM double-door seals |
|---|---|
| Panel Thickness | 50-120 mm compatible barrier-wall thickness |
| Effective Width | 105-350 mm nominal transfer-port diameter |
| Maximum Length | Up to 800 mm beta container length |
| Steel Facing Thickness | 1.2-2.0 mm stainless beta container wall |
| Core Density | 1100-1250 kg/m³ for elastomer sealing components |
| Thermal Conductivity | 0.20-0.30 W/(m·K) for elastomer sealing material |
| Surface Finish | Satin 316L stainless steel with smooth white polymer ring and blue cleanroom seal |
| Joint Type | Rotational alpha-beta docking interface with coupled double doors, mechanical interlock and replaceable circular seal |
| Customization | Available based on the intended application and operating environment. |