A weatherproof outdoor air handler that places filtration and thermal treatment on the roof while preserving indoor production floor space.
  • Weatherproof Outdoor Casing
  • Roof-Curb Integration
  • Serviceable Roof Access
  • Configurable Air Treatment
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

A rooftop air handling unit packages the air-treatment sequence in a corrosion-protected, insulated enclosure designed for wind, rain, solar exposure and seasonal temperature extremes. Sloped roof panels, sealed service doors, intake hoods and base-frame drainage prevent water entry. Supply and return openings align with a roof curb or external duct risers, and access is arranged from a safe service side. The unit can be supply-only, recirculating or fitted with separated heat recovery according to the clean-facility ventilation strategy.

الخصائص الرئيسية

Sloped weather caps and sealed exterior joints shed rain away from service openings.

A continuous structural base transfers unit load and seals to the roof curb or support steel.

UV-stable coating and corrosion-resistant fasteners protect the outdoor casing over long-term exposure.

Intake hoods, drainable coil sections and freeze protection support year-round outdoor operation.

مخاوف المنتج للعملاء

Moving air-handling equipment outdoors saves internal space but exposes every casing joint, door and drain to weather.

Wind-driven rain enters around a flat service door or intake opening.Raised thresholds, compression seals and drained weather hoods protect the air path.
Solar heat and cold ambient conditions increase casing heat gain and condensation risk.Thick thermal-break panels reduce conduction through skins and frame profiles.
An uneven roof curb twists the unit base and opens panel joints.A rigid perimeter base and matched curb distribute load and provide a level sealing surface.
Routine filter or fan service requires unsafe access around the roof edge.All regular service points are grouped on the designated safe side of the unit.

تطبيقات نموذجية

Clean manufacturing buildings with limited plant spacePharmaceutical roof plantsLaboratory ventilation systemsHealthcare clean facilitiesIndustrial outdoor-air treatment

المعلمات الفنية

Typical outdoor casing construction for a rooftop air handling unit is listed below.

المواد الأساسيةClosed-cell polyurethane or non-combustible mineral-wool insulation in double-skin weather casing
سمك اللوحة50–75 mm insulated weatherproof panel
العرض الفعال1200–4000 mm nominal rooftop unit width
الحد الأقصى الطولUp to 14000 mm in weather-sealed shipping sections
الصلب يواجه سمك0.8–1.2 mm outer skin and 0.6–1.0 mm inner skin
الكثافة الأساسية40–45 kg/m³ polyurethane or 92–120 kg/m³ mineral wool
الموصلية الحرارية0.022–0.040 W/(m·K), according to outdoor panel core
إنهاء السطحUV-resistant polyester powder coat over galvanized or Aluzinc steel
نوع المشتركWeather-gasketed thermal-break panels on a continuous bolted roof-base frame
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

Factory roof curb and vibration isolationSupply-only, mixed-air or heat-recovery layoutRain hood, bird screen and motorized dampersCold-climate preheat and freeze protection

Planning a Rooftop Air Handling Unit specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat

الرئيسية

المنتجات

الأخبار

من نحن

اتصل بنا