클린룸 장비 및 무균 시설 필수품의 원스톱 공급업체국제 프로젝트 지원
Open mobile navigationClose mobile navigation
/ 제품 / 클린룸 HVAC 및 공기 처리 장비 / Rooftop Air Handling Unit
클린룸 HVAC 및 공기 처리 장비

옥상 공기 처리 장치 Rooftop Air Handling Unit

A weatherproof outdoor air handler that places filtration and thermal treatment on the roof while preserving indoor production floor space.
  • Weatherproof Outdoor Casing
  • Roof-Curb Integration
  • Serviceable Roof Access
  • Configurable Air Treatment
견적 요청 제품 찾아보기

상품 소개

A rooftop air handling unit packages the air-treatment sequence in a corrosion-protected, insulated enclosure designed for wind, rain, solar exposure and seasonal temperature extremes. Sloped roof panels, sealed service doors, intake hoods and base-frame drainage prevent water entry. Supply and return openings align with a roof curb or external duct risers, and access is arranged from a safe service side. The unit can be supply-only, recirculating or fitted with separated heat recovery according to the clean-facility ventilation strategy.

주요 기능

Sloped weather caps and sealed exterior joints shed rain away from service openings.

A continuous structural base transfers unit load and seals to the roof curb or support steel.

UV-stable coating and corrosion-resistant fasteners protect the outdoor casing over long-term exposure.

Intake hoods, drainable coil sections and freeze protection support year-round outdoor operation.

고객 제품 관심사

Moving air-handling equipment outdoors saves internal space but exposes every casing joint, door and drain to weather.

Wind-driven rain enters around a flat service door or intake opening.Raised thresholds, compression seals and drained weather hoods protect the air path.
Solar heat and cold ambient conditions increase casing heat gain and condensation risk.Thick thermal-break panels reduce conduction through skins and frame profiles.
An uneven roof curb twists the unit base and opens panel joints.A rigid perimeter base and matched curb distribute load and provide a level sealing surface.
Routine filter or fan service requires unsafe access around the roof edge.All regular service points are grouped on the designated safe side of the unit.

일반적인 응용 프로그램

Clean manufacturing buildings with limited plant spacePharmaceutical roof plantsLaboratory ventilation systemsHealthcare clean facilitiesIndustrial outdoor-air treatment

기술 매개변수

Typical outdoor casing construction for a rooftop air handling unit is listed below.

핵심 재료Closed-cell polyurethane or non-combustible mineral-wool insulation in double-skin weather casing
패널 두께50–75 mm insulated weatherproof panel
유효 폭1200–4000 mm nominal rooftop unit width
최대 길이Up to 14000 mm in weather-sealed shipping sections
강철 면면 두께0.8–1.2 mm outer skin and 0.6–1.0 mm inner skin
코어 밀도40–45 kg/m³ polyurethane or 92–120 kg/m³ mineral wool
열전도도 (Thermal Conductivity)0.022–0.040 W/(m·K), according to outdoor panel core
표면 마무리UV-resistant polyester powder coat over galvanized or Aluzinc steel
접합 유형Weather-gasketed thermal-break panels on a continuous bolted roof-base frame
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.