موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
مرشحات الهواء والترشيح الكيميائي

العادم HEPA تصفية الإسكان

A sealed wall or ceiling housing that captures contaminated room exhaust through a room-side replaceable HEPA filter before it enters the duct system.
  • Negative-Pressure Service
  • Room-Side Replacement
  • Optional Prefilter Door
  • Integrated Test Connections
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The exhaust HEPA housing mounts at the room boundary so contaminated air crosses the filter before entering shared ductwork. A welded box, sealed inlet grille and compression clamp keep the dirty side confined to a shallow room-side zone. The front panel can include an integral prefilter and opens for filter replacement without disturbing the downstream duct. Pressure sampling, aerosol injection and scan access can be incorporated around the sealing frame.

الخصائص الرئيسية

Boundary placement captures particulate contamination before the exhaust duct.

Room-side filter access supports service where ceiling-void entry is restricted.

A hinged prefilter face intercepts lint and extends the life of the HEPA element.

Integrated test connections allow seal and resistance checks at the terminal.

مخاوف المنتج للعملاء

An exhaust terminal must prevent contaminated room air from bypassing into the common duct and remain serviceable under negative pressure.

Contaminants enter the duct before reaching a remote central filter.A terminal HEPA element captures particles at the room boundary.
Lint loads the HEPA face and raises room negative pressure.A removable coarse prefilter intercepts larger debris ahead of the absolute filter.
The sealing edge cannot be inspected from the occupied space.Room-side clamps expose the gasket or gel interface after the grille is removed.
Testing disturbs ductwork shared with adjacent rooms.Local pressure and aerosol ports keep verification focused on the individual terminal.

تطبيقات نموذجية

Hospital isolation roomsMicrobiology laboratory exhaustPharmaceutical weighing boothsAnimal holding suitesControlled decontamination rooms

المعلمات الفنية

Typical construction ranges for a room-side exhaust HEPA housing are shown below.

المواد الأساسيةFully welded galvanized or 304 stainless-steel box with stainless room-side filter clamp
سمك اللوحة1.0–1.5 mm enclosure panels
العرض الفعال305–915 mm nominal filter face width
الحد الأقصى الطولUp to 1220 mm nominal terminal length
الصلب يواجه سمك1.0–1.5 mm housing and grille sheet
الكثافة الأساسيةApproximately 7850–8000 kg/m³ for steel housing parts
الموصلية الحراريةApproximately 15–50 W/(m·K) for the selected exhaust-box sheet construction
إنهاء السطحWhite powder coat or brushed stainless finish with smooth cleanable face
نوع المشتركWelded terminal box with room-side gasket or gel filter seal and flanged exhaust spigot
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

Wall or ceiling mountingGasket- or gel-seal HEPAIntegral prefilter grillePressure and aerosol test ports

التخطيط لمواصفات تصفية العادم HEPA الإسكان؟

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat