Egzoz HEPA Filtre Konutları

A sealed wall or ceiling housing that captures contaminated room exhaust through a room-side replaceable HEPA filter before it enters the duct system.
  • Negative-Pressure Service
  • Room-Side Replacement
  • Optional Prefilter Door
  • Integrated Test Connections
Alıntı isteği Browse ürünleri

Ürün tanıtımı

The exhaust HEPA housing mounts at the room boundary so contaminated air crosses the filter before entering shared ductwork. A welded box, sealed inlet grille and compression clamp keep the dirty side confined to a shallow room-side zone. The front panel can include an integral prefilter and opens for filter replacement without disturbing the downstream duct. Pressure sampling, aerosol injection and scan access can be incorporated around the sealing frame.

Ana Özellikler

Boundary placement captures particulate contamination before the exhaust duct.

Room-side filter access supports service where ceiling-void entry is restricted.

A hinged prefilter face intercepts lint and extends the life of the HEPA element.

Integrated test connections allow seal and resistance checks at the terminal.

Müşteri Ürün Sorunları

An exhaust terminal must prevent contaminated room air from bypassing into the common duct and remain serviceable under negative pressure.

Contaminants enter the duct before reaching a remote central filter.A terminal HEPA element captures particles at the room boundary.
Lint loads the HEPA face and raises room negative pressure.A removable coarse prefilter intercepts larger debris ahead of the absolute filter.
The sealing edge cannot be inspected from the occupied space.Room-side clamps expose the gasket or gel interface after the grille is removed.
Testing disturbs ductwork shared with adjacent rooms.Local pressure and aerosol ports keep verification focused on the individual terminal.

Tipik uygulamalar

Hospital isolation roomsMicrobiology laboratory exhaustPharmaceutical weighing boothsAnimal holding suitesControlled decontamination rooms

Teknik parametreler

Typical construction ranges for a room-side exhaust HEPA housing are shown below.

Temel malzemelerFully welded galvanized or 304 stainless-steel box with stainless room-side filter clamp
Panel kalınlığı1.0–1.5 mm enclosure panels
Effective Width (Etkili Genişlik)305–915 mm nominal filter face width
Maksimum uzunlukUp to 1220 mm nominal terminal length
Çelik yüz yüze kalınlığı1.0–1.5 mm housing and grille sheet
Core Density (Çekirdek Yoğunluğu)Approximately 7850–8000 kg/m³ for steel housing parts
Termal İletkenlikApproximately 15–50 W/(m·K) for the selected exhaust-box sheet construction
Yüzey bitirmeWhite powder coat or brushed stainless finish with smooth cleanable face
Ortak tipWelded terminal box with room-side gasket or gel filter seal and flanged exhaust spigot
Customization (Özelleşme)Kullanılan uygulama ve çalışma ortamına göre kullanılabilir.

Mevcut Seçenekler

Wall or ceiling mountingGasket- or gel-seal HEPAIntegral prefilter grillePressure and aerosol test ports