Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Accueil / Produits / Filtres à air et filtration chimique / Exhaust HEPA Filter Housing
Filtres à air et filtration chimique

Filtre d'échappement HEPA

A sealed wall or ceiling housing that captures contaminated room exhaust through a room-side replaceable HEPA filter before it enters the duct system.
  • Negative-Pressure Service
  • Room-Side Replacement
  • Optional Prefilter Door
  • Integrated Test Connections
Demander un devis. Browse les produits

Introduction de produit

The exhaust HEPA housing mounts at the room boundary so contaminated air crosses the filter before entering shared ductwork. A welded box, sealed inlet grille and compression clamp keep the dirty side confined to a shallow room-side zone. The front panel can include an integral prefilter and opens for filter replacement without disturbing the downstream duct. Pressure sampling, aerosol injection and scan access can be incorporated around the sealing frame.

Key Features

Boundary placement captures particulate contamination before the exhaust duct.

Room-side filter access supports service where ceiling-void entry is restricted.

A hinged prefilter face intercepts lint and extends the life of the HEPA element.

Integrated test connections allow seal and resistance checks at the terminal.

Préoccupations du client produit

An exhaust terminal must prevent contaminated room air from bypassing into the common duct and remain serviceable under negative pressure.

Contaminants enter the duct before reaching a remote central filter.A terminal HEPA element captures particles at the room boundary.
Lint loads the HEPA face and raises room negative pressure.A removable coarse prefilter intercepts larger debris ahead of the absolute filter.
The sealing edge cannot be inspected from the occupied space.Room-side clamps expose the gasket or gel interface after the grille is removed.
Testing disturbs ductwork shared with adjacent rooms.Local pressure and aerosol ports keep verification focused on the individual terminal.

Les applications typiques

Hospital isolation roomsMicrobiology laboratory exhaustPharmaceutical weighing boothsAnimal holding suitesControlled decontamination rooms

Paramètres techniques

Typical construction ranges for a room-side exhaust HEPA housing are shown below.

Matériaux de baseFully welded galvanized or 304 stainless-steel box with stainless room-side filter clamp
Panneau épaisseur1.0–1.5 mm enclosure panels
Largeur effective305–915 mm nominal filter face width
Longueur maximaleUp to 1220 mm nominal terminal length
Acier face épaisseur1.0–1.5 mm housing and grille sheet
Densité CoreApproximately 7850–8000 kg/m³ for steel housing parts
Conductivité thermiqueApproximately 15–50 W/(m·K) for the selected exhaust-box sheet construction
surface finieWhite powder coat or brushed stainless finish with smooth cleanable face
Type jointWelded terminal box with room-side gasket or gel filter seal and flanged exhaust spigot
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

Wall or ceiling mountingGasket- or gel-seal HEPAIntegral prefilter grillePressure and aerosol test ports