クリーンルーム機器と無菌施設の必需品のワンストップサプライヤー国際プロジェクト支援
Open mobile navigationClose mobile navigation
ホーム / 製品 / エアフィルターと化学ろ過 / Exhaust HEPA Filter Housing
エアフィルターと化学ろ過

排気 HEPA フィルターハウジング

A sealed wall or ceiling housing that captures contaminated room exhaust through a room-side replaceable HEPA filter before it enters the duct system.
  • Negative-Pressure Service
  • Room-Side Replacement
  • Optional Prefilter Door
  • Integrated Test Connections
見積もりリクエスト 製品案内

商品紹介

The exhaust HEPA housing mounts at the room boundary so contaminated air crosses the filter before entering shared ductwork. A welded box, sealed inlet grille and compression clamp keep the dirty side confined to a shallow room-side zone. The front panel can include an integral prefilter and opens for filter replacement without disturbing the downstream duct. Pressure sampling, aerosol injection and scan access can be incorporated around the sealing frame.

主要な特徴

Boundary placement captures particulate contamination before the exhaust duct.

Room-side filter access supports service where ceiling-void entry is restricted.

A hinged prefilter face intercepts lint and extends the life of the HEPA element.

Integrated test connections allow seal and resistance checks at the terminal.

お客様の製品に関する懸念事項

An exhaust terminal must prevent contaminated room air from bypassing into the common duct and remain serviceable under negative pressure.

Contaminants enter the duct before reaching a remote central filter.A terminal HEPA element captures particles at the room boundary.
Lint loads the HEPA face and raises room negative pressure.A removable coarse prefilter intercepts larger debris ahead of the absolute filter.
The sealing edge cannot be inspected from the occupied space.Room-side clamps expose the gasket or gel interface after the grille is removed.
Testing disturbs ductwork shared with adjacent rooms.Local pressure and aerosol ports keep verification focused on the individual terminal.

典型的な用途

Hospital isolation roomsMicrobiology laboratory exhaustPharmaceutical weighing boothsAnimal holding suitesControlled decontamination rooms

技術的なパラメータ

Typical construction ranges for a room-side exhaust HEPA housing are shown below.

コア材料Fully welded galvanized or 304 stainless-steel box with stainless room-side filter clamp
パネルの厚さ1.0–1.5 mm enclosure panels
有効幅305–915 mm nominal filter face width
最大長さUp to 1220 mm nominal terminal length
鋼鉄の厚さを直面する1.0–1.5 mm housing and grille sheet
コア密度Approximately 7850–8000 kg/m³ for steel housing parts
熱伝導率Approximately 15–50 W/(m·K) for the selected exhaust-box sheet construction
表面仕上げWhite powder coat or brushed stainless finish with smooth cleanable face
ジョイントタイプWelded terminal box with room-side gasket or gel filter seal and flanged exhaust spigot
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

利用可能なオプション

Wall or ceiling mountingGasket- or gel-seal HEPAIntegral prefilter grillePressure and aerosol test ports

Planning a Exhaust HEPA Filter Housing specification?

寸法、設置条件、性能目標、必要な表面仕上げをお送りください。

チームに相談する
メール送信 WhatsApp WeChat

ホーム

製品

ニュース

会社概要

お問い合わせ