Kuru Oda Hava İşleme Birimi
- Desiccant Rotor Drying
- Low Dew-Point Supply
- Separated Regeneration Air
- High Recirculation Efficiency
Ürün tanıtımı
The dry room air handling unit removes water vapor beyond the practical range of cooling coils by passing process air through a continuously regenerated desiccant rotor. A pre-cooling stage reduces incoming moisture load, the rotor performs deep drying, and post-cooling controls supply temperature. A separate heated regeneration airstream removes captured moisture from the rotor and discharges it outdoors. Recirculating most of the dry-room air limits the outdoor moisture load, while sealed casing and low-leakage dampers protect the achieved dew point.
Ana Özellikler
Separated process and regeneration air paths prevent wet regeneration exhaust from mixing with dry supply air.
Pre-cooling and sensible post-cooling reduce rotor load and set the final supply temperature.
High dry-air recirculation minimizes the quantity of humid outdoor air that requires deep treatment.
Müşteri Ürün Sorunları
Ultra-low humidity is easily lost through casing leakage, door infiltration, wet regeneration carryover and moisture released by process materials.
Tipik uygulamalar
Teknik parametreler
Typical insulated casing construction for an integrated dry-room air handling unit is summarized below.
| Temel malzemeler | Closed-cell polyurethane insulation with silica-gel or molecular-sieve desiccant rotor media |
|---|---|
| Panel kalınlığı | 60–100 mm low-leakage insulated casing |
| Effective Width (Etkili Genişlik) | 1200–4200 mm nominal equipment width |
| Maksimum uzunluk | Up to 15000 mm including process and regeneration treatment sections |
| Çelik yüz yüze kalınlığı | 0.8–1.2 mm coated or stainless casing skins |
| Core Density (Çekirdek Yoğunluğu) | 40–45 kg/m³ polyurethane panel insulation |
| Termal İletkenlik | 0.022–0.026 W/(m·K) for casing insulation |
| Yüzey bitirme | Powder-coated exterior with sealed galvanized or stainless cleanable inner surfaces |
| Ortak tip | Compression-gasketed low-leakage panels with sealed process and regeneration air paths |
| Customization (Özelleşme) | Kullanılan uygulama ve çalışma ortamına göre kullanılabilir. |
Mevcut Seçenekler
Planning a Dry Room Air Handling Unit specification?
Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.

İngilizce
Almanca
Arapça
Fransızca
Endonezya dilinde
Japonca
Korece
Malay dilinde
Portekizce
Rusça
İspanyolca
Taylandca
TürkçeCurrent
Vietnamca