Dry Room Luftbehandlungseinheit

An integrated desiccant air handler that combines deep moisture removal, regeneration, cooling and recirculation for ultra-dry production rooms.
  • Desiccant Rotor Drying
  • Low Dew-Point Supply
  • Separated Regeneration Air
  • High Recirculation Efficiency

Produkteinführung

The dry room air handling unit removes water vapor beyond the practical range of cooling coils by passing process air through a continuously regenerated desiccant rotor. A pre-cooling stage reduces incoming moisture load, the rotor performs deep drying, and post-cooling controls supply temperature. A separate heated regeneration airstream removes captured moisture from the rotor and discharges it outdoors. Recirculating most of the dry-room air limits the outdoor moisture load, while sealed casing and low-leakage dampers protect the achieved dew point.

Key Features

A desiccant rotor removes vapor at dew points where condensation-based cooling becomes inefficient.

Separated process and regeneration air paths prevent wet regeneration exhaust from mixing with dry supply air.

Pre-cooling and sensible post-cooling reduce rotor load and set the final supply temperature.

High dry-air recirculation minimizes the quantity of humid outdoor air that requires deep treatment.

Kunden Produktbedenken

Ultra-low humidity is easily lost through casing leakage, door infiltration, wet regeneration carryover and moisture released by process materials.

A chilled-water coil cannot reach the required dry-room dew point.The desiccant rotor adsorbs remaining vapor after the air is precooled.
Regeneration exhaust leaks into the dry process airstream.Sealed rotor sectors, pressure control and purge arrangements limit cross-stream carryover.
Opening personnel or material doors causes slow humidity recovery.Sufficient recirculation airflow and controlled dry-air make-up remove the infiltration moisture load.
Reactivation heat dominates system energy use.Purge optimization, heat recovery and the appropriate steam, gas, electric or heat-pump source reduce regeneration demand.

Typische Anwendungen

Lithium-ion battery dry roomsMoisture-sensitive pharmaceutical processingDry powder productionElectronics and component storageResearch-scale ultra-dry laboratories

Technische Parameter

Typical insulated casing construction for an integrated dry-room air handling unit is summarized below.

Core MaterialClosed-cell polyurethane insulation with silica-gel or molecular-sieve desiccant rotor media
Panel Dicke60–100 mm low-leakage insulated casing
Effektive Breite1200–4200 mm nominal equipment width
Maximale LängeUp to 15000 mm including process and regeneration treatment sections
Stahl facing Dicke0.8–1.2 mm coated or stainless casing skins
Kerndichte40–45 kg/m³ polyurethane panel insulation
Thermische Leitfähigkeit0.022–0.026 W/(m·K) for casing insulation
Oberfläche FinishPowder-coated exterior with sealed galvanized or stainless cleanable inner surfaces
Gemeinsamer TypCompression-gasketed low-leakage panels with sealed process and regeneration air paths
CustomisierungVerfügbar je nach beabsichtigter Anwendung und Betriebsumgebung.

Verfügbare Optionen

Silica-gel or molecular-sieve rotorSteam, gas, electric or heat-pump regenerationDeep-drying single or multi-stage arrangementHeat recovery and purge-sector optimization