Unit pengendalian udara bilik kering
- Desiccant Rotor Drying
- Low Dew-Point Supply
- Separated Regeneration Air
- High Recirculation Efficiency
Pengenalan Produk
The dry room air handling unit removes water vapor beyond the practical range of cooling coils by passing process air through a continuously regenerated desiccant rotor. A pre-cooling stage reduces incoming moisture load, the rotor performs deep drying, and post-cooling controls supply temperature. A separate heated regeneration airstream removes captured moisture from the rotor and discharges it outdoors. Recirculating most of the dry-room air limits the outdoor moisture load, while sealed casing and low-leakage dampers protect the achieved dew point.
Ciri-ciri Utama
Separated process and regeneration air paths prevent wet regeneration exhaust from mixing with dry supply air.
Pre-cooling and sensible post-cooling reduce rotor load and set the final supply temperature.
High dry-air recirculation minimizes the quantity of humid outdoor air that requires deep treatment.
Kebimbangan Produk Pelanggan
Ultra-low humidity is easily lost through casing leakage, door infiltration, wet regeneration carryover and moisture released by process materials.
Permohonan yang biasa
Parameter teknikal
Typical insulated casing construction for an integrated dry-room air handling unit is summarized below.
| Bahan Teras | Closed-cell polyurethane insulation with silica-gel or molecular-sieve desiccant rotor media |
|---|---|
| Ketebalan Panel | 60–100 mm low-leakage insulated casing |
| Lebar berkesan | 1200–4200 mm nominal equipment width |
| Panjang maksimum | Up to 15000 mm including process and regeneration treatment sections |
| Keluli Menghadapi Ketebalan | 0.8–1.2 mm coated or stainless casing skins |
| Ketumpatan teras | 40–45 kg/m³ polyurethane panel insulation |
| Kekonduksian Terma | 0.022–0.026 W/(m·K) for casing insulation |
| Kemasan permukaan | Powder-coated exterior with sealed galvanized or stainless cleanable inner surfaces |
| Jenis Bersatu | Compression-gasketed low-leakage panels with sealed process and regeneration air paths |
| Penyesuaian | Boleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi. |
Pilihan yang boleh didapati
Planning a Dry Room Air Handling Unit specification?
Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Bahasa Inggeris
Bahasa Jerman
Bahasa Arab (Bahasa Melayu)
Bahasa Perancis
Bahasa Indonesia: Bahasa Indonesia
Bahasa Jepun
Bahasa Korea (Bahasa Melayu)
Bahasa Melayu (Bahasa Melayu)Semasa
Bahasa Portugis: Bahasa Portugis: Bahasa Portugis
Bahasa Rusia
Bahasa Sepanyol: Bahasa Sepanyol: Bahasa Sepanyol
Bahasa Melayu (Bahasa Melayu)
Bahasa Turki: Bahasa Turki
Bahasa Vietnam (Bahasa Melayu)