An engineered gaseous suppression package that discharges without water or cleanup residue in critical equipment spaces.
  • Residue-Free Gaseous Discharge
  • Supervised Cylinder Bank
  • Engineered Nozzle Network
  • Integrated Releasing Controls
Alıntı isteği Browse ürünleri

Ürün tanıtımı

The clean-agent system stores the selected extinguishing medium in supervised cylinders connected to a calculated distribution network. Detection and releasing controls manage alarm verification, shutdown interfaces and discharge sequencing, while pressure switches report system operation. Cylinder capacity, nozzle orifices and room integrity requirements are engineered for the actual protected volume and hazard.

Ana Özellikler

Gaseous discharge avoids water damage and post-event powder cleanup.

Supervised valves and pressure contacts report system readiness.

Calculated pipe and nozzle sizing distributes agent through the protected enclosure.

Releasing controls coordinate alarms, ventilation shutdown and manual abort functions.

Müşteri Ürün Sorunları

Critical electronics need rapid fire suppression without conductive water or persistent residue, yet discharge must remain engineered for occupant and enclosure conditions.

Water discharge can damage energized controls and clean equipment.The selected clean agent suppresses fire as a gas and leaves no particulate residue.
An undersized agent quantity fails to reach the design concentration.Cylinder capacity is calculated from protected volume, leakage and design conditions.
Open dampers allow agent to escape before hold time is achieved.The release panel coordinates ventilation shutdown and closure interfaces.
Accidental discharge disrupts production.Cross-zoned detection, manual abort and supervised circuits support controlled release logic.

Tipik uygulamalar

Cleanroom control roomsProcess equipment enclosuresElectrical switch roomsCritical data and instrumentation spaces

Teknik parametreler

Typical cylinder-bank construction values are listed below; agent quantity, nozzle drilling and release logic remain specific to the protected hazard.

Temel malzemelerPainted steel agent cylinders with brass valves and steel or stainless distribution pipe
Panel kalınlığı2.5-6.0 mm cylinder wall depending on pressure and capacity
Effective Width (Etkili Genişlik)300-1800 mm cylinder-bank width
Maksimum uzunlukUp to 2200 mm cylinder and manifold height
Çelik yüz yüze kalınlığı1.2-2.0 mm releasing-control enclosure panels
Core Density (Çekirdek Yoğunluğu)7850 kg/m³ for steel pressure-vessel parts
Termal İletkenlik45-60 W/(m·K) for carbon-steel components
Yüzey bitirmeRed or white protective coating with corrosion-resistant valve hardware
Ortak tipHigh-pressure threaded or flared manifold with supervised discharge valves
Customization (Özelleşme)Kullanılan uygulama ve çalışma ortamına göre kullanılabilir.

Mevcut Seçenekler

Single or multi-cylinder bankMain/reserve arrangementLocal releasing panelRemote alarm and shutdown interfaces