Оборудование воздуха для рекуперации тепла
- Separated Supply and Exhaust
- Selectable Recovery Technology
- Bypass and Frost Control
- Reduced Outdoor-Air Load
Введение продукции
The heat recovery air handling unit brings outdoor supply and building exhaust through a common insulated casing while maintaining defined separation between air streams. Counterflow plate exchangers offer no moving transfer surface, rotary wheels provide high sensible and latent recovery where appropriate, and run-around coils completely separate the ducts. Bypass dampers, frost control and independent fans keep airflow stable through changing outdoor conditions. The recovery method is chosen according to contamination-transfer tolerance, humidity objectives and physical duct arrangement.
Основные характеристики
Independent supply and exhaust fans maintain balanced airflow through different filter-loading conditions.
Bypass and frost-control sequences protect the exchanger during extreme ambient operation.
Accessible recovery cassettes and drain sections simplify inspection and cleaning.
Обеспокоенность клиентов продуктами
Energy recovery is valuable only when cross-stream leakage, frost, condensate and fan balance are controlled for the actual exhaust source.
Типичные приложения
Технические параметры
Representative casing data for a dual-stream heat-recovery air handling unit are shown below.
| Основной материал | Closed-cell polyurethane or mineral-wool insulation in separated double-skin air paths |
|---|---|
| Толщина панели | 50–60 mm insulated casing |
| эффективная ширина | 1000–3200 mm nominal unit width |
| Максимальная длина | Up to 10000 mm including recovery, filter, coil and fan sections |
| Толщина линий стали | 0.6–1.0 mm galvanized, coated or stainless sheet skins |
| Плотность ядра | 40–44 kg/m³ polyurethane or 86–100 kg/m³ mineral wool |
| Теплопроводимость | 0.022–0.040 W/(m·K) for the casing insulation |
| Поверхностная отделка | Powder-coated exterior with cleanable galvanized or stainless inner lining |
| Объединенный тип | Gasketed dual-stream casing with sealed recovery cassette and independent duct collars |
| Customization | Доступно в зависимости от предполагаемого применения и операционной среды. |
Доступные варианты
Planning a Heat Recovery Air Handling Unit specification?
Отправьте нам ваши габариты, условия монтажа, целевые показатели производительности и требуемую отделку поверхности.