Recuperación de calor Unidad de manejo de aire
- Separated Supply and Exhaust
- Selectable Recovery Technology
- Bypass and Frost Control
- Reduced Outdoor-Air Load
Introducción del producto
The heat recovery air handling unit brings outdoor supply and building exhaust through a common insulated casing while maintaining defined separation between air streams. Counterflow plate exchangers offer no moving transfer surface, rotary wheels provide high sensible and latent recovery where appropriate, and run-around coils completely separate the ducts. Bypass dampers, frost control and independent fans keep airflow stable through changing outdoor conditions. The recovery method is chosen according to contamination-transfer tolerance, humidity objectives and physical duct arrangement.
Características clave
Independent supply and exhaust fans maintain balanced airflow through different filter-loading conditions.
Bypass and frost-control sequences protect the exchanger during extreme ambient operation.
Accessible recovery cassettes and drain sections simplify inspection and cleaning.
Preocupaciones del producto del cliente
Energy recovery is valuable only when cross-stream leakage, frost, condensate and fan balance are controlled for the actual exhaust source.
Aplicaciones típicas
Parámetros técnicos
Representative casing data for a dual-stream heat-recovery air handling unit are shown below.
| Materiales Core | Closed-cell polyurethane or mineral-wool insulation in separated double-skin air paths |
|---|---|
| Panel de espesor | 50–60 mm insulated casing |
| Ancho efectivo | 1000–3200 mm nominal unit width |
| Longitud máxima | Up to 10000 mm including recovery, filter, coil and fan sections |
| Acero frente a espesor | 0.6–1.0 mm galvanized, coated or stainless sheet skins |
| Densidad Core | 40–44 kg/m³ polyurethane or 86–100 kg/m³ mineral wool |
| Conductividad térmica | 0.022–0.040 W/(m·K) for the casing insulation |
| Superficie acabada | Powder-coated exterior with cleanable galvanized or stainless inner lining |
| Tipo conjunto | Gasketed dual-stream casing with sealed recovery cassette and independent duct collars |
| Customization | Disponible según la aplicación prevista y el entorno operativo. |
Opciones disponibles
Planning a Heat Recovery Air Handling Unit specification?
Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.