Pemulihan haba Unit Pengendalian Udara
- Separated Supply and Exhaust
- Selectable Recovery Technology
- Bypass and Frost Control
- Reduced Outdoor-Air Load
Pengenalan Produk
The heat recovery air handling unit brings outdoor supply and building exhaust through a common insulated casing while maintaining defined separation between air streams. Counterflow plate exchangers offer no moving transfer surface, rotary wheels provide high sensible and latent recovery where appropriate, and run-around coils completely separate the ducts. Bypass dampers, frost control and independent fans keep airflow stable through changing outdoor conditions. The recovery method is chosen according to contamination-transfer tolerance, humidity objectives and physical duct arrangement.
Ciri-ciri Utama
Independent supply and exhaust fans maintain balanced airflow through different filter-loading conditions.
Bypass and frost-control sequences protect the exchanger during extreme ambient operation.
Accessible recovery cassettes and drain sections simplify inspection and cleaning.
Kebimbangan Produk Pelanggan
Energy recovery is valuable only when cross-stream leakage, frost, condensate and fan balance are controlled for the actual exhaust source.
Permohonan yang biasa
Parameter teknikal
Representative casing data for a dual-stream heat-recovery air handling unit are shown below.
| Bahan Teras | Closed-cell polyurethane or mineral-wool insulation in separated double-skin air paths |
|---|---|
| Ketebalan Panel | 50–60 mm insulated casing |
| Lebar berkesan | 1000–3200 mm nominal unit width |
| Panjang maksimum | Up to 10000 mm including recovery, filter, coil and fan sections |
| Keluli Menghadapi Ketebalan | 0.6–1.0 mm galvanized, coated or stainless sheet skins |
| Ketumpatan teras | 40–44 kg/m³ polyurethane or 86–100 kg/m³ mineral wool |
| Kekonduksian Terma | 0.022–0.040 W/(m·K) for the casing insulation |
| Kemasan permukaan | Powder-coated exterior with cleanable galvanized or stainless inner lining |
| Jenis Bersatu | Gasketed dual-stream casing with sealed recovery cassette and independent duct collars |
| Penyesuaian | Boleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi. |
Pilihan yang boleh didapati
Planning a Heat Recovery Air Handling Unit specification?
Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Bahasa Inggeris
Bahasa Jerman
Bahasa Arab (Bahasa Melayu)
Bahasa Perancis
Bahasa Indonesia: Bahasa Indonesia
Bahasa Jepun
Bahasa Korea (Bahasa Melayu)
Bahasa Melayu (Bahasa Melayu)Semasa
Bahasa Portugis: Bahasa Portugis: Bahasa Portugis
Bahasa Rusia
Bahasa Sepanyol: Bahasa Sepanyol: Bahasa Sepanyol
Bahasa Melayu (Bahasa Melayu)
Bahasa Turki: Bahasa Turki
Bahasa Vietnam (Bahasa Melayu)