Đơn vị xử lý không khí phục hồi nhiệt

A dual-air-stream unit that transfers useful heat between exhaust and outdoor air while keeping filtration and airflow control independently serviceable.
  • Separated Supply and Exhaust
  • Selectable Recovery Technology
  • Bypass and Frost Control
  • Reduced Outdoor-Air Load
Yêu cầu báo giá Duyệt các sản phẩm

Giới thiệu Sản phẩm

The heat recovery air handling unit brings outdoor supply and building exhaust through a common insulated casing while maintaining defined separation between air streams. Counterflow plate exchangers offer no moving transfer surface, rotary wheels provide high sensible and latent recovery where appropriate, and run-around coils completely separate the ducts. Bypass dampers, frost control and independent fans keep airflow stable through changing outdoor conditions. The recovery method is chosen according to contamination-transfer tolerance, humidity objectives and physical duct arrangement.

Các tính năng chính

Three recovery approaches allow energy transfer to match air-separation and moisture requirements.

Independent supply and exhaust fans maintain balanced airflow through different filter-loading conditions.

Bypass and frost-control sequences protect the exchanger during extreme ambient operation.

Accessible recovery cassettes and drain sections simplify inspection and cleaning.

Các mối quan tâm về sản phẩm của khách hàng

Energy recovery is valuable only when cross-stream leakage, frost, condensate and fan balance are controlled for the actual exhaust source.

Exhaust contaminants can cross into the clean supply air through the wrong recovery device.A plate or run-around system is selected where physical stream separation is the priority.
Ice blocks the exchanger during cold outdoor operation.Temperature-based bypass, preheat or controlled defrost limits frost accumulation.
Unequal supply and exhaust pressure drives leakage across a rotary wheel.Fan control and purge-section arrangement establish the intended pressure relationship.
Condensate remains under a plate exchanger and reaches adjacent panels.A full-width sloped drain pan collects water from the complete recovery section.

Các ứng dụng điển hình

Cleanroom ventilation systemsLaboratories with high exhaustHealthcare clean facilitiesPharmaceutical productionEnergy-conscious industrial ventilation

Thông số kỹ thuật

Representative casing data for a dual-stream heat-recovery air handling unit are shown below.

Vật liệu lõiClosed-cell polyurethane or mineral-wool insulation in separated double-skin air paths
Độ dày bảng điều khiển50–60 mm insulated casing
Chiều rộng hiệu quả1000–3200 mm nominal unit width
Chiều dài tối đaUp to 10000 mm including recovery, filter, coil and fan sections
Thép đối mặt với độ dày0.6–1.0 mm galvanized, coated or stainless sheet skins
Mật độ lõi40–44 kg/m³ polyurethane or 86–100 kg/m³ mineral wool
Độ dẫn nhiệt0.022–0.040 W/(m·K) for the casing insulation
Kết thúc bề mặtPowder-coated exterior with cleanable galvanized or stainless inner lining
Loại khớp nốiGasketed dual-stream casing with sealed recovery cassette and independent duct collars
Tùy chỉnhCó sẵn dựa trên ứng dụng dự định và môi trường hoạt động.

Các tùy chọn có sẵn

Counterflow plate heat exchangerRotary sensible or enthalpy wheelRun-around coil recovery loopBypass damper, preheat and frost-control package