/ 제품 / 클린룸 HVAC 및 공기 처리 장비 / Heat Recovery Air Handling Unit
클린룸 HVAC 및 공기 처리 장비

열회수 공기처리 유닛

A dual-air-stream unit that transfers useful heat between exhaust and outdoor air while keeping filtration and airflow control independently serviceable.
  • Separated Supply and Exhaust
  • Selectable Recovery Technology
  • Bypass and Frost Control
  • Reduced Outdoor-Air Load
견적 요청 제품 찾아보기

상품 소개

The heat recovery air handling unit brings outdoor supply and building exhaust through a common insulated casing while maintaining defined separation between air streams. Counterflow plate exchangers offer no moving transfer surface, rotary wheels provide high sensible and latent recovery where appropriate, and run-around coils completely separate the ducts. Bypass dampers, frost control and independent fans keep airflow stable through changing outdoor conditions. The recovery method is chosen according to contamination-transfer tolerance, humidity objectives and physical duct arrangement.

주요 기능

Three recovery approaches allow energy transfer to match air-separation and moisture requirements.

Independent supply and exhaust fans maintain balanced airflow through different filter-loading conditions.

Bypass and frost-control sequences protect the exchanger during extreme ambient operation.

Accessible recovery cassettes and drain sections simplify inspection and cleaning.

고객 제품 관심사

Energy recovery is valuable only when cross-stream leakage, frost, condensate and fan balance are controlled for the actual exhaust source.

Exhaust contaminants can cross into the clean supply air through the wrong recovery device.A plate or run-around system is selected where physical stream separation is the priority.
Ice blocks the exchanger during cold outdoor operation.Temperature-based bypass, preheat or controlled defrost limits frost accumulation.
Unequal supply and exhaust pressure drives leakage across a rotary wheel.Fan control and purge-section arrangement establish the intended pressure relationship.
Condensate remains under a plate exchanger and reaches adjacent panels.A full-width sloped drain pan collects water from the complete recovery section.

일반적인 응용 프로그램

Cleanroom ventilation systemsLaboratories with high exhaustHealthcare clean facilitiesPharmaceutical productionEnergy-conscious industrial ventilation

기술 매개변수

Representative casing data for a dual-stream heat-recovery air handling unit are shown below.

핵심 재료Closed-cell polyurethane or mineral-wool insulation in separated double-skin air paths
패널 두께50–60 mm insulated casing
유효 폭1000–3200 mm nominal unit width
최대 길이Up to 10000 mm including recovery, filter, coil and fan sections
강철 면면 두께0.6–1.0 mm galvanized, coated or stainless sheet skins
코어 밀도40–44 kg/m³ polyurethane or 86–100 kg/m³ mineral wool
열전도도 (Thermal Conductivity)0.022–0.040 W/(m·K) for the casing insulation
표면 마무리Powder-coated exterior with cleanable galvanized or stainless inner lining
접합 유형Gasketed dual-stream casing with sealed recovery cassette and independent duct collars
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

사용 가능한 옵션

Counterflow plate heat exchangerRotary sensible or enthalpy wheelRun-around coil recovery loopBypass damper, preheat and frost-control package