Ваш универсальный поставщик оборудования для чистых помещений и асептических средствПоддержка международных проектов
Open mobile navigationClose mobile navigation
Оборудование для ламинарного потока и ограничения

Класс III кабинет биологической безопасности

A closed gas-tight biological safety glovebox that separates the operator from the work through fixed gloves, negative pressure and controlled transfer ports.
  • Gas-Tight Stainless Chamber
  • Fixed Glove and Sleeve Ports
  • Negative-Pressure Operation
  • Controlled Double-Door Transfer
Запрос котировки Просмотреть продукты

Введение продукции

The Class III cabinet is a fully enclosed stainless steel glovebox operated under negative pressure. Manipulation is performed through fixed glove and sleeve assemblies rather than an open front sash. Materials enter through an interlocked double-door pass chamber or other sealed transfer interface, and exhaust air passes through high-efficiency filtration before connection to the facility exhaust. Welded chamber seams, pressure monitoring and glove integrity management form the physical containment boundary.

Основные характеристики

A welded gas-tight chamber provides complete physical separation from the operator.

Replaceable glove and sleeve assemblies support manipulation without opening the cabinet.

A double-door transfer chamber controls material entry and removal.

Negative pressure directs any inward leakage toward the filtered exhaust.

Pressure-hold and glove-integrity connections support routine barrier checks.

Обеспокоенность клиентов продуктами

A gas-tight glovebox depends on every welded seam, glove port, transfer door and exhaust connection remaining part of one controlled barrier.

Opening the main chamber would break the containment boundary.A double-door transfer chamber moves materials without opening the operator workspace.
Gloves are the most frequently stressed barrier component.Replaceable port rings and integrity-test connections support routine glove management.
A positive leak could release chamber air.Negative pressure directs leakage inward toward the filtered exhaust.
Internal corners are difficult to decontaminate.Welded radiused stainless geometry reduces inaccessible crevices.

Типичные приложения

High-risk biological researchContained pathogen manipulationSpecialized animal or sample processingClosed biological procedure development

Технические параметры

Typical configurable construction ranges for a Class III biological safety cabinet are listed below.

Основной материалFully welded SUS316L chamber with laminated safety-glass viewing panel and butyl or CSM glove assemblies
Толщина панели40-80 mm double-skin chamber and service sections
эффективная ширина1200-3000 mm usable glovebox width
Максимальная длинаUp to 4000 mm overall chamber length
Толщина линий стали2.0-3.0 mm welded SUS316L chamber shell
Плотность ядраApproximately 8000 kg/m³ for SUS316L chamber material
Теплопроводимость14-16 W/(m·K) for austenitic stainless steel
Поверхностная отделкаElectropolished SUS316L interior with radiused welded corners
Объединенный типContinuously welded pressure-tight chamber with sealed glove rings, double-door transfer hatch and flanged exhaust
CustomizationДоступно в зависимости от предполагаемого применения и операционной среды.

Доступные варианты

Two to eight glove positionsPass-through autoclave interfaceDunk tank or rapid transfer portIntegrated pressure-hold test connections

Planning a Class III Biological Safety Cabinet specification?

Отправьте нам ваши габариты, условия монтажа, целевые показатели производительности и требуемую отделку поверхности.

Поговорите с нашей командой
Электронная почта WhatsApp WeChat