Kabinet Keamanan Biologi Kelas III
- Gas-Tight Stainless Chamber
- Fixed Glove and Sleeve Ports
- Negative-Pressure Operation
- Controlled Double-Door Transfer
Perkenalan produk
The Class III cabinet is a fully enclosed stainless steel glovebox operated under negative pressure. Manipulation is performed through fixed glove and sleeve assemblies rather than an open front sash. Materials enter through an interlocked double-door pass chamber or other sealed transfer interface, and exhaust air passes through high-efficiency filtration before connection to the facility exhaust. Welded chamber seams, pressure monitoring and glove integrity management form the physical containment boundary.
Fitur utama:
Replaceable glove and sleeve assemblies support manipulation without opening the cabinet.
A double-door transfer chamber controls material entry and removal.
Negative pressure directs any inward leakage toward the filtered exhaust.
Pressure-hold and glove-integrity connections support routine barrier checks.
Kekhawatiran produk pelanggan
A gas-tight glovebox depends on every welded seam, glove port, transfer door and exhaust connection remaining part of one controlled barrier.
Aplikasi yang Tipis
Parameter teknis
Typical configurable construction ranges for a Class III biological safety cabinet are listed below.
| Bahan inti | Fully welded SUS316L chamber with laminated safety-glass viewing panel and butyl or CSM glove assemblies |
|---|---|
| Ketebalan Panel (Panel Thickness) | 40-80 mm double-skin chamber and service sections |
| Efektif lebar | 1200-3000 mm usable glovebox width |
| Panjang maksimum | Up to 4000 mm overall chamber length |
| Baja menghadap ketebalan | 2.0-3.0 mm welded SUS316L chamber shell |
| Kepadatan inti (core density) | Approximately 8000 kg/m³ for SUS316L chamber material |
| Konduktivitas Termal (Thermal Conductivity) | 14 - 16 W / (m · K) untuk baja tahan karat austenitic |
| Permukaan selesai | Electropolished SUS316L interior with radiused welded corners |
| Jenis Bersama | Continuously welded pressure-tight chamber with sealed glove rings, double-door transfer hatch and flanged exhaust |
| Customization (Kustomisasi) | Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi. |
Pilihan yang tersedia
Planning a Class III Biological Safety Cabinet specification?
Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.