Cabinet de sécurité biologique de classe III par
- Gas-Tight Stainless Chamber
- Fixed Glove and Sleeve Ports
- Negative-Pressure Operation
- Controlled Double-Door Transfer
Introduction de produit
The Class III cabinet is a fully enclosed stainless steel glovebox operated under negative pressure. Manipulation is performed through fixed glove and sleeve assemblies rather than an open front sash. Materials enter through an interlocked double-door pass chamber or other sealed transfer interface, and exhaust air passes through high-efficiency filtration before connection to the facility exhaust. Welded chamber seams, pressure monitoring and glove integrity management form the physical containment boundary.
Key Features
Replaceable glove and sleeve assemblies support manipulation without opening the cabinet.
A double-door transfer chamber controls material entry and removal.
Negative pressure directs any inward leakage toward the filtered exhaust.
Pressure-hold and glove-integrity connections support routine barrier checks.
Préoccupations du client produit
A gas-tight glovebox depends on every welded seam, glove port, transfer door and exhaust connection remaining part of one controlled barrier.
Les applications typiques
Paramètres techniques
Typical configurable construction ranges for a Class III biological safety cabinet are listed below.
| Matériaux de base | Fully welded SUS316L chamber with laminated safety-glass viewing panel and butyl or CSM glove assemblies |
|---|---|
| Panneau épaisseur | 40-80 mm double-skin chamber and service sections |
| Largeur effective | 1200-3000 mm usable glovebox width |
| Longueur maximale | Up to 4000 mm overall chamber length |
| Acier face épaisseur | 2.0-3.0 mm welded SUS316L chamber shell |
| Densité Core | Approximately 8000 kg/m³ for SUS316L chamber material |
| Conductivité thermique | 14 - 16 W / (m · K) pour l'acier inoxydable austénitique par |
| surface finie | Electropolished SUS316L interior with radiused welded corners |
| Type joint | Continuously welded pressure-tight chamber with sealed glove rings, double-door transfer hatch and flanged exhaust |
| Customisation | Disponible en fonction de l'application prévue et de l'environnement d'exploitation. |
Options disponibles
Planning a Class III Biological Safety Cabinet specification?
Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Anglais
Allemand
Arabe
FrançaisCurrent
Indonésien
Japonais
Coréen
Le malais
Le portugais
russe
espagnol
Thaïlandais
Le turc