Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Équipement d'écoulement et de confinement laminaires

Cabinet de sécurité biologique de classe III par

A closed gas-tight biological safety glovebox that separates the operator from the work through fixed gloves, negative pressure and controlled transfer ports.
  • Gas-Tight Stainless Chamber
  • Fixed Glove and Sleeve Ports
  • Negative-Pressure Operation
  • Controlled Double-Door Transfer
Demander un devis. Browse les produits

Introduction de produit

The Class III cabinet is a fully enclosed stainless steel glovebox operated under negative pressure. Manipulation is performed through fixed glove and sleeve assemblies rather than an open front sash. Materials enter through an interlocked double-door pass chamber or other sealed transfer interface, and exhaust air passes through high-efficiency filtration before connection to the facility exhaust. Welded chamber seams, pressure monitoring and glove integrity management form the physical containment boundary.

Key Features

A welded gas-tight chamber provides complete physical separation from the operator.

Replaceable glove and sleeve assemblies support manipulation without opening the cabinet.

A double-door transfer chamber controls material entry and removal.

Negative pressure directs any inward leakage toward the filtered exhaust.

Pressure-hold and glove-integrity connections support routine barrier checks.

Préoccupations du client produit

A gas-tight glovebox depends on every welded seam, glove port, transfer door and exhaust connection remaining part of one controlled barrier.

Opening the main chamber would break the containment boundary.A double-door transfer chamber moves materials without opening the operator workspace.
Gloves are the most frequently stressed barrier component.Replaceable port rings and integrity-test connections support routine glove management.
A positive leak could release chamber air.Negative pressure directs leakage inward toward the filtered exhaust.
Internal corners are difficult to decontaminate.Welded radiused stainless geometry reduces inaccessible crevices.

Les applications typiques

High-risk biological researchContained pathogen manipulationSpecialized animal or sample processingClosed biological procedure development

Paramètres techniques

Typical configurable construction ranges for a Class III biological safety cabinet are listed below.

Matériaux de baseFully welded SUS316L chamber with laminated safety-glass viewing panel and butyl or CSM glove assemblies
Panneau épaisseur40-80 mm double-skin chamber and service sections
Largeur effective1200-3000 mm usable glovebox width
Longueur maximaleUp to 4000 mm overall chamber length
Acier face épaisseur2.0-3.0 mm welded SUS316L chamber shell
Densité CoreApproximately 8000 kg/m³ for SUS316L chamber material
Conductivité thermique14 - 16 W / (m · K) pour l'acier inoxydable austénitique par
surface finieElectropolished SUS316L interior with radiused welded corners
Type jointContinuously welded pressure-tight chamber with sealed glove rings, double-door transfer hatch and flanged exhaust
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

Two to eight glove positionsPass-through autoclave interfaceDunk tank or rapid transfer portIntegrated pressure-hold test connections

Planning a Class III Biological Safety Cabinet specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe