Kelas III Kabinet Keselamatan Biologi
- Gas-Tight Stainless Chamber
- Fixed Glove and Sleeve Ports
- Negative-Pressure Operation
- Controlled Double-Door Transfer
Pengenalan Produk
The Class III cabinet is a fully enclosed stainless steel glovebox operated under negative pressure. Manipulation is performed through fixed glove and sleeve assemblies rather than an open front sash. Materials enter through an interlocked double-door pass chamber or other sealed transfer interface, and exhaust air passes through high-efficiency filtration before connection to the facility exhaust. Welded chamber seams, pressure monitoring and glove integrity management form the physical containment boundary.
Ciri-ciri Utama
Replaceable glove and sleeve assemblies support manipulation without opening the cabinet.
A double-door transfer chamber controls material entry and removal.
Negative pressure directs any inward leakage toward the filtered exhaust.
Pressure-hold and glove-integrity connections support routine barrier checks.
Kebimbangan Produk Pelanggan
A gas-tight glovebox depends on every welded seam, glove port, transfer door and exhaust connection remaining part of one controlled barrier.
Permohonan yang biasa
Parameter teknikal
Typical configurable construction ranges for a Class III biological safety cabinet are listed below.
| Bahan Teras | Fully welded SUS316L chamber with laminated safety-glass viewing panel and butyl or CSM glove assemblies |
|---|---|
| Ketebalan Panel | 40-80 mm double-skin chamber and service sections |
| Lebar berkesan | 1200-3000 mm usable glovebox width |
| Panjang maksimum | Up to 4000 mm overall chamber length |
| Keluli Menghadapi Ketebalan | 2.0-3.0 mm welded SUS316L chamber shell |
| Ketumpatan teras | Approximately 8000 kg/m³ for SUS316L chamber material |
| Kekonduksian Terma | 14-16 W / (m · K) untuk keluli tahan karat austenit |
| Kemasan permukaan | Electropolished SUS316L interior with radiused welded corners |
| Jenis Bersatu | Continuously welded pressure-tight chamber with sealed glove rings, double-door transfer hatch and flanged exhaust |
| Penyesuaian | Boleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi. |
Pilihan yang boleh didapati
Planning a Class III Biological Safety Cabinet specification?
Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Bahasa Inggeris
Bahasa Jerman
Bahasa Arab (Bahasa Melayu)
Bahasa Perancis
Bahasa Indonesia: Bahasa Indonesia
Bahasa Jepun
Bahasa Korea (Bahasa Melayu)
Bahasa Melayu (Bahasa Melayu)Semasa
Bahasa Portugis: Bahasa Portugis: Bahasa Portugis
Bahasa Rusia
Bahasa Sepanyol: Bahasa Sepanyol: Bahasa Sepanyol
Bahasa Melayu (Bahasa Melayu)
Bahasa Turki: Bahasa Turki
Bahasa Vietnam (Bahasa Melayu)