Duas pessoas chuveiro de ar limpo

A widened personnel air shower that cleans two gowned operators per cycle through distributed filtered-air nozzles and split low-level returns.
  • Two-Operator Capacity
  • Expanded Nozzle Zones
  • Wide Controlled Doorway
  • Split Return Collection
Solicite um orçamento. Browse produtos

Introdução do produto

This two-person air shower enlarges the usable chamber and scales the airflow system rather than merely widening a single-person shell. Multiple nozzle zones correspond to two standing positions, and split returns collect contamination from both portions of the floor area. It suits shift entries where paired traffic is common but a long walk-through tunnel is unnecessary.

Características-chave

A wider clear floor gives two gowned operators space to stand apart.

Additional outlet rows extend cleaning air across both occupied positions.

Multiple fan sections support airflow delivery over the enlarged nozzle array.

Split return grilles shorten the collection path from each standing zone.

Reinforced door framing supports a wider personnel opening.

Preocupações do produto do cliente

Paired entry must raise throughput without allowing one operator to block the other from the cleaning airflow.

Two occupants can crowd together and shield garment surfaces.A widened floor plan and distributed nozzles establish two usable cleaning positions.
A single blower can lose pressure as chamber width and nozzle count increase.Multiple centrifugal blower sections divide the demand across the enlarged air circuit.
A broad door leaf can lose alignment after repeated cycles.Reinforced jambs and adjustable hardware maintain the relationship between the door and interlock.
The larger particle load overwhelms a small return area.Separate lower return sections offer greater collection area on both sides of the chamber.

Aplicações típicas

Pharmaceutical shift entrancesBattery production clean areasMedical consumables manufacturingFood-packaging hygiene zones

Parâmetros técnicos

Typical ranges for a two-occupant cleanroom air shower are shown below.

Material principalPolyurethane-insulated steel enclosure with multiple centrifugal blowers, stainless nozzles, prefilters and H13 HEPA filters
Painel de espessura50-60 mm insulated chamber panels
Largura efetiva1000-1400 mm clear two-person passage width
Comprimento máximoUp to 2000 mm cleaning-zone length
Aço enfrentando espessura1.0-1.2 mm enclosure facing with reinforced door jambs
Densidade Core40-45 kg/m³ rigid polyurethane insulation
Condutividade térmica0.023-0.029 W/(m·K) for the closed-cell panel core
Superfície acabadoWhite cleanroom powder coat with polished stainless jet nozzles
Tipo conjuntoReinforced flush panel joints with a gasketed wide-door frame and electromagnetic interlock
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Opções disponíveis

24-32 directional nozzlesSingle or double-leaf doorsIndependent blower-filter circuitsOccupancy and voice-prompt display