معدات إزالة التلوث للموظفين والمواد
شخصين غرف نظيفة هواء دش
A widened personnel air shower that cleans two gowned operators per cycle through distributed filtered-air nozzles and split low-level returns.
- Two-Operator Capacity
- Expanded Nozzle Zones
- Wide Controlled Doorway
- Split Return Collection
مقدمة المنتج
This two-person air shower enlarges the usable chamber and scales the airflow system rather than merely widening a single-person shell. Multiple nozzle zones correspond to two standing positions, and split returns collect contamination from both portions of the floor area. It suits shift entries where paired traffic is common but a long walk-through tunnel is unnecessary.
الخصائص الرئيسية
Additional outlet rows extend cleaning air across both occupied positions.
Multiple fan sections support airflow delivery over the enlarged nozzle array.
Split return grilles shorten the collection path from each standing zone.
Reinforced door framing supports a wider personnel opening.
مخاوف المنتج للعملاء
Paired entry must raise throughput without allowing one operator to block the other from the cleaning airflow.
Two occupants can crowd together and shield garment surfaces.A widened floor plan and distributed nozzles establish two usable cleaning positions.
A single blower can lose pressure as chamber width and nozzle count increase.Multiple centrifugal blower sections divide the demand across the enlarged air circuit.
A broad door leaf can lose alignment after repeated cycles.Reinforced jambs and adjustable hardware maintain the relationship between the door and interlock.
The larger particle load overwhelms a small return area.Separate lower return sections offer greater collection area on both sides of the chamber.
تطبيقات نموذجية
Pharmaceutical shift entrancesBattery production clean areasMedical consumables manufacturingFood-packaging hygiene zones
المعلمات الفنية
Typical ranges for a two-occupant cleanroom air shower are shown below.
| المواد الأساسية | Polyurethane-insulated steel enclosure with multiple centrifugal blowers, stainless nozzles, prefilters and H13 HEPA filters |
|---|---|
| سمك اللوحة | 50-60 mm insulated chamber panels |
| العرض الفعال | 1000-1400 mm clear two-person passage width |
| الحد الأقصى الطول | Up to 2000 mm cleaning-zone length |
| الصلب يواجه سمك | 1.0-1.2 mm enclosure facing with reinforced door jambs |
| الكثافة الأساسية | 40-45 kg/m³ rigid polyurethane insulation |
| الموصلية الحرارية | 0.023-0.029 W/(m·K) for the closed-cell panel core |
| إنهاء السطح | White cleanroom powder coat with polished stainless jet nozzles |
| نوع المشترك | Reinforced flush panel joints with a gasketed wide-door frame and electromagnetic interlock |
| التخصيص | متوفر على أساس التطبيق المقصود وبيئة التشغيل. |
الخيارات المتاحة
24-32 directional nozzlesSingle or double-leaf doorsIndependent blower-filter circuitsOccupancy and voice-prompt display
Planning a Two-Person Cleanroom Air Shower specification?
أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

English
الألمانية
العربيةالحالي
الفرنسية
الإندونيسية
اليابانية
الكورية
اللغة الملاوية
البرتغالية
الروسية
الإسبانية
التايلاندية
اللغة التركية
اللغة الفيتنامية