Su proveedor de ventanilla única para equipos de sala limpia y elementos esenciales para instalaciones asépticasApoyo a proyectos internacionales
Open mobile navigationClose mobile navigation
Equipos de descontaminación de personal y material

Ducha de aire limpio para dos personas

A widened personnel air shower that cleans two gowned operators per cycle through distributed filtered-air nozzles and split low-level returns.
  • Two-Operator Capacity
  • Expanded Nozzle Zones
  • Wide Controlled Doorway
  • Split Return Collection
Solicite un presupuesto. Browse productos

Introducción del producto

This two-person air shower enlarges the usable chamber and scales the airflow system rather than merely widening a single-person shell. Multiple nozzle zones correspond to two standing positions, and split returns collect contamination from both portions of the floor area. It suits shift entries where paired traffic is common but a long walk-through tunnel is unnecessary.

Características clave

A wider clear floor gives two gowned operators space to stand apart.

Additional outlet rows extend cleaning air across both occupied positions.

Multiple fan sections support airflow delivery over the enlarged nozzle array.

Split return grilles shorten the collection path from each standing zone.

Reinforced door framing supports a wider personnel opening.

Preocupaciones del producto del cliente

Paired entry must raise throughput without allowing one operator to block the other from the cleaning airflow.

Two occupants can crowd together and shield garment surfaces.A widened floor plan and distributed nozzles establish two usable cleaning positions.
A single blower can lose pressure as chamber width and nozzle count increase.Multiple centrifugal blower sections divide the demand across the enlarged air circuit.
A broad door leaf can lose alignment after repeated cycles.Reinforced jambs and adjustable hardware maintain the relationship between the door and interlock.
The larger particle load overwhelms a small return area.Separate lower return sections offer greater collection area on both sides of the chamber.

Aplicaciones típicas

Pharmaceutical shift entrancesBattery production clean areasMedical consumables manufacturingFood-packaging hygiene zones

Parámetros técnicos

Typical ranges for a two-occupant cleanroom air shower are shown below.

Materiales CorePolyurethane-insulated steel enclosure with multiple centrifugal blowers, stainless nozzles, prefilters and H13 HEPA filters
Panel de espesor50-60 mm insulated chamber panels
Ancho efectivo1000-1400 mm clear two-person passage width
Longitud máximaUp to 2000 mm cleaning-zone length
Acero frente a espesor1.0-1.2 mm enclosure facing with reinforced door jambs
Densidad Core40-45 kg/m³ rigid polyurethane insulation
Conductividad térmica0.023-0.029 W/(m·K) for the closed-cell panel core
Superficie acabadaWhite cleanroom powder coat with polished stainless jet nozzles
Tipo conjuntoReinforced flush panel joints with a gasketed wide-door frame and electromagnetic interlock
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

24-32 directional nozzlesSingle or double-leaf doorsIndependent blower-filter circuitsOccupancy and voice-prompt display

Planning a Two-Person Cleanroom Air Shower specification?

Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Habla con nuestro equipo
E-mail Nos WhatsApp WeChat

Inicio

Productos

Noticias

Nosotros

Contacto