Equipos de descontaminación de personal y material
Ducha de aire limpio para dos personas
A widened personnel air shower that cleans two gowned operators per cycle through distributed filtered-air nozzles and split low-level returns.
- Two-Operator Capacity
- Expanded Nozzle Zones
- Wide Controlled Doorway
- Split Return Collection
Introducción del producto
This two-person air shower enlarges the usable chamber and scales the airflow system rather than merely widening a single-person shell. Multiple nozzle zones correspond to two standing positions, and split returns collect contamination from both portions of the floor area. It suits shift entries where paired traffic is common but a long walk-through tunnel is unnecessary.
Características clave
Additional outlet rows extend cleaning air across both occupied positions.
Multiple fan sections support airflow delivery over the enlarged nozzle array.
Split return grilles shorten the collection path from each standing zone.
Reinforced door framing supports a wider personnel opening.
Preocupaciones del producto del cliente
Paired entry must raise throughput without allowing one operator to block the other from the cleaning airflow.
Two occupants can crowd together and shield garment surfaces.A widened floor plan and distributed nozzles establish two usable cleaning positions.
A single blower can lose pressure as chamber width and nozzle count increase.Multiple centrifugal blower sections divide the demand across the enlarged air circuit.
A broad door leaf can lose alignment after repeated cycles.Reinforced jambs and adjustable hardware maintain the relationship between the door and interlock.
The larger particle load overwhelms a small return area.Separate lower return sections offer greater collection area on both sides of the chamber.
Aplicaciones típicas
Pharmaceutical shift entrancesBattery production clean areasMedical consumables manufacturingFood-packaging hygiene zones
Parámetros técnicos
Typical ranges for a two-occupant cleanroom air shower are shown below.
| Materiales Core | Polyurethane-insulated steel enclosure with multiple centrifugal blowers, stainless nozzles, prefilters and H13 HEPA filters |
|---|---|
| Panel de espesor | 50-60 mm insulated chamber panels |
| Ancho efectivo | 1000-1400 mm clear two-person passage width |
| Longitud máxima | Up to 2000 mm cleaning-zone length |
| Acero frente a espesor | 1.0-1.2 mm enclosure facing with reinforced door jambs |
| Densidad Core | 40-45 kg/m³ rigid polyurethane insulation |
| Conductividad térmica | 0.023-0.029 W/(m·K) for the closed-cell panel core |
| Superficie acabada | White cleanroom powder coat with polished stainless jet nozzles |
| Tipo conjunto | Reinforced flush panel joints with a gasketed wide-door frame and electromagnetic interlock |
| Customization | Disponible según la aplicación prevista y el entorno operativo. |
Opciones disponibles
24-32 directional nozzlesSingle or double-leaf doorsIndependent blower-filter circuitsOccupancy and voice-prompt display
Planning a Two-Person Cleanroom Air Shower specification?
Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Inglés
Alemán
El árabe
Francés
Idioma indonesio
El japonés
Coreano
El malayo
El portugués
El ruso
EspañolCurrent
Tailandés
El turco
El vietnamita