Seu fornecedor único para equipamentos de sala limpa e instalações assépticas essenciaisApoio Internacional a Projetos
Open mobile navigationClose mobile navigation
Fluxo laminar e equipamentos de contenção

Módulo de fluxo laminar de teto

A modular ceiling array that joins multiple HEPA filter and diffuser sections into one continuous unidirectional downflow field above a larger process zone.
  • Multi-Module Filter Array
  • Continuous Downflow Field
  • Sealed Ceiling Grid
  • Room-Side Service Options
Solicite um orçamento. Browse produtos

Introdução do produto

This ceiling system combines multiple fan-filter or terminal HEPA sections within a sealed support grid. Blank panels, lighting modules and service penetrations are integrated without opening uncontrolled gaps in the airflow field. Adjustable grid suspension maintains a flat lower plane across larger process equipment, while the modular arrangement allows filter sections to match the required footprint. It is typically used where one standalone hood cannot cover the full aseptic operation.

Características-chave

Repeating filter modules create a scalable airflow footprint above long or wide equipment.

Sealed blank panels close areas not occupied by filters, lights or service penetrations.

A common support grid keeps adjacent diffuser faces aligned at one level.

Room-side replaceable modules can reduce access work in the technical ceiling void.

Integrated pressure ports support section-by-section filter condition checks.

Preocupações do produto do cliente

Large process footprints require a continuous clean-air field without misaligned modules, open ceiling joints or unserviceable filters.

Separate hoods leave uncontrolled gaps over a long line.A connected modular grid extends one coordinated airflow field across the selected footprint.
Filter modules sit at different heights after installation.Adjustable suspension points level the complete lower diffuser plane.
Lights and services interrupt filter coverage.Sealed compatible lighting and penetration modules fit within the same grid.
Technical-ceiling access is restricted above equipment.Room-side service filter frames can be selected where overhead access is unavailable.

Aplicações típicas

Aseptic filling line coverageOpen-container process zonesSterile component stagingLarge clean assembly areas

Parâmetros técnicos

Typical configurable construction ranges for a modular laminar flow ceiling are listed below.

Material principalExtruded aluminum support grid with powder-coated steel filter housings and aluminum honeycomb diffuser panels
Painel de espessura70-150 mm filter and diffuser module depth
Largura efetiva1200-6000 mm assembled ceiling width
Comprimento máximoUp to 12000 mm assembled airflow-field length
Aço enfrentando espessura0.8-1.2 mm powder-coated steel filter housings and blank panels
Densidade Core30-50 kg/m³ aluminum honeycomb diffuser core
Condutividade térmica1.5-2.5 W/(m·K) across the diffuser-panel assembly
Superfície acabadoWhite powder-coated modules with natural or white anodized grid sections
Tipo conjuntoGasketed modular T-grid with sealed filter frames, blank panels and service penetrations
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Opções disponíveis

Fan-filter or terminal-filter modulesIntegrated flush LED panelsRoom-side replaceable filtersCustom blank and service panels

Planning a Laminar Flow Ceiling Module specification?

Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Fale com a nossa equipe
Email-nos O WhatsApp WeChat

Início

Produtos

Notícias

Sobre nós

Contato