Unidade de Manuseio de Ar Higiênico
- Drainable Wet Sections
- Corrosion-Resistant Interior
- Removable Treatment Components
- Accessible Cleanable Surfaces
Introdução do produto
The hygienic air handling unit emphasizes internal access, drainage and material compatibility wherever treated air may affect sensitive occupants or products. Smooth metal lining covers insulation and frame cavities, service doors provide access to both faces of coils and filters, and condensate pans extend beneath the complete coil and eliminator assembly. Fans are selected without belt debris in the airstream, and seals use closed-cell materials that do not retain moisture. The result is a serviceable unit for hospitals, food processing and hygiene-critical manufacturing.
Características-chave
Coil sections use fully drainable pans and accessible eliminators to control water carryover.
Pull-out filters, coils and service panels reduce inaccessible surfaces during periodic cleaning.
Direct-drive fans remove belts and pulleys from the treated airstream.
Preocupações do produto do cliente
Hygienic air treatment fails when moisture, retained debris or inaccessible surfaces remain inside the equipment between maintenance intervals.
Aplicações típicas
Parâmetros técnicos
Representative construction data for a hygiene-oriented air handling unit are shown below.
| Material principal | Non-hygroscopic closed-cell polyurethane or sealed high-density mineral-wool insulation |
|---|---|
| Painel de espessura | 50–70 mm hygienic double-skin casing |
| Largura efetiva | 1000–3800 mm nominal casing width |
| Comprimento máximo | Up to 12000 mm in cleanable modular sections |
| Aço enfrentando espessura | 0.8–1.2 mm internal liner and 0.6–1.0 mm external skin |
| Densidade Core | 42–45 kg/m³ polyurethane or 90–120 kg/m³ mineral wool |
| Condutividade térmica | 0.022–0.040 W/(m·K), based on selected casing insulation |
| Superfície acabado | Smooth 304 stainless-steel or coated galvanized interior with powder-coated exterior |
| Tipo conjunto | Flush sealed panel joints with closed-cell gaskets and radiused internal transitions |
| Customização | Disponível com base na aplicação pretendida e no ambiente operacional. |
Opções disponíveis