Гигиенические установки по обработке воздуха
- Drainable Wet Sections
- Corrosion-Resistant Interior
- Removable Treatment Components
- Accessible Cleanable Surfaces
Введение продукции
The hygienic air handling unit emphasizes internal access, drainage and material compatibility wherever treated air may affect sensitive occupants or products. Smooth metal lining covers insulation and frame cavities, service doors provide access to both faces of coils and filters, and condensate pans extend beneath the complete coil and eliminator assembly. Fans are selected without belt debris in the airstream, and seals use closed-cell materials that do not retain moisture. The result is a serviceable unit for hospitals, food processing and hygiene-critical manufacturing.
Основные характеристики
Coil sections use fully drainable pans and accessible eliminators to control water carryover.
Pull-out filters, coils and service panels reduce inaccessible surfaces during periodic cleaning.
Direct-drive fans remove belts and pulleys from the treated airstream.
Обеспокоенность клиентов продуктами
Hygienic air treatment fails when moisture, retained debris or inaccessible surfaces remain inside the equipment between maintenance intervals.
Типичные приложения
Технические параметры
Representative construction data for a hygiene-oriented air handling unit are shown below.
| Основной материал | Non-hygroscopic closed-cell polyurethane or sealed high-density mineral-wool insulation |
|---|---|
| Толщина панели | 50–70 mm hygienic double-skin casing |
| эффективная ширина | 1000–3800 mm nominal casing width |
| Максимальная длина | Up to 12000 mm in cleanable modular sections |
| Толщина линий стали | 0.8–1.2 mm internal liner and 0.6–1.0 mm external skin |
| Плотность ядра | 42–45 kg/m³ polyurethane or 90–120 kg/m³ mineral wool |
| Теплопроводимость | 0.022–0.040 W/(m·K), based on selected casing insulation |
| Поверхностная отделка | Smooth 304 stainless-steel or coated galvanized interior with powder-coated exterior |
| Объединенный тип | Flush sealed panel joints with closed-cell gaskets and radiused internal transitions |
| Customization | Доступно в зависимости от предполагаемого применения и операционной среды. |
Доступные варианты
Planning a Hygienic Air Handling Unit specification?
Отправьте нам ваши габариты, условия монтажа, целевые показатели производительности и требуемую отделку поверхности.