Unit Penanganan Udara Hygienic
- Drainable Wet Sections
- Corrosion-Resistant Interior
- Removable Treatment Components
- Accessible Cleanable Surfaces
Perkenalan produk
The hygienic air handling unit emphasizes internal access, drainage and material compatibility wherever treated air may affect sensitive occupants or products. Smooth metal lining covers insulation and frame cavities, service doors provide access to both faces of coils and filters, and condensate pans extend beneath the complete coil and eliminator assembly. Fans are selected without belt debris in the airstream, and seals use closed-cell materials that do not retain moisture. The result is a serviceable unit for hospitals, food processing and hygiene-critical manufacturing.
Fitur utama:
Coil sections use fully drainable pans and accessible eliminators to control water carryover.
Pull-out filters, coils and service panels reduce inaccessible surfaces during periodic cleaning.
Direct-drive fans remove belts and pulleys from the treated airstream.
Kekhawatiran produk pelanggan
Hygienic air treatment fails when moisture, retained debris or inaccessible surfaces remain inside the equipment between maintenance intervals.
Aplikasi yang Tipis
Parameter teknis
Representative construction data for a hygiene-oriented air handling unit are shown below.
| Bahan inti | Non-hygroscopic closed-cell polyurethane or sealed high-density mineral-wool insulation |
|---|---|
| Ketebalan Panel (Panel Thickness) | 50–70 mm hygienic double-skin casing |
| Efektif lebar | 1000–3800 mm nominal casing width |
| Panjang maksimum | Up to 12000 mm in cleanable modular sections |
| Baja menghadap ketebalan | 0.8–1.2 mm internal liner and 0.6–1.0 mm external skin |
| Kepadatan inti (core density) | 42–45 kg/m³ polyurethane or 90–120 kg/m³ mineral wool |
| Konduktivitas Termal (Thermal Conductivity) | 0.022–0.040 W/(m·K), based on selected casing insulation |
| Permukaan selesai | Smooth 304 stainless-steel or coated galvanized interior with powder-coated exterior |
| Jenis Bersama | Flush sealed panel joints with closed-cell gaskets and radiused internal transitions |
| Customization (Kustomisasi) | Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi. |
Pilihan yang tersedia
Planning a Hygienic Air Handling Unit specification?
Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.

Bahasa Inggris
Bahasa Jerman
Bahasa Arab
Bahasa Perancis: Bahasa Perancis
Bahasa IndonesiaSaat ini
Bahasa Jepang
Bahasa Korea
Bahasa Melayu
Bahasa Portugis
Bahasa Rusia
Bahasa Spanyol
Bahasa Thailand
Bahasa Turki
Bahasa Vietnam