A supervised leak sensor that detects conductive liquid along a cable or zone probe near cleanroom utilities and reports an alarm before water spreads.
  • Sensing Cable or Zone Probe
  • Supervised Circuit Integrity
  • Fast Local Alarm
  • BMS Relay Output
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The water leak detection sensor monitors the electrical condition of a floor cable, rope sensor or compact zone probe. Contact with conductive liquid changes the sensing circuit and activates the local controller, while supervision identifies cable breaks or disconnected probes separately. The sensing element can be routed around AHU drain pans, humidifiers, chilled-water lines and raised-floor utility paths. Relay or network output sends leak and trouble states to the BMS so response can begin before water reaches clean finishes or sensitive equipment.

الخصائص الرئيسية

Flexible sensing cable follows equipment perimeters and long utility routes.

Circuit supervision distinguishes a leak alarm from a broken or disconnected sensor.

Resettable sensing elements can return to service after cleaning and drying.

Separate relay or network states report leak, cable fault and controller health.

مخاوف المنتج للعملاء

A useful leak system must cover the likely water path, remain serviceable and signal cable damage before an actual leak occurs.

A point probe detects water only after it reaches one small location.A sensing cable follows the full perimeter or lowest likely flow path.
A disconnected cable leaves the area unprotected without warning.Supervised end-of-line monitoring creates a distinct trouble alarm for circuit loss.
The sensor must be discarded after a minor clean-water leak.A resettable cable can be wiped, dried and returned to monitoring service.
Water spreads under equipment before staff find the source zone.Zoned circuits and clear controller labels narrow the response area quickly.

تطبيقات نموذجية

AHU and humidifier roomsCleanroom utility chasesRaised-floor process areasChilled-water and drain lines

المعلمات الفنية

Typical construction values for a cleanroom water leak sensor and zone controller are listed below.

المواد الأساسيةConductive polymer sensing cable with fluoropolymer braid and polycarbonate zone controller
سمك اللوحة35-70 mm controller depth
العرض الفعال90-160 mm controller width
الحد الأقصى الطولSensing cable zones up to 30000 mm
الصلب يواجه سمك0-1.0 mm; optional stainless mounting plate
الكثافة الأساسية1700-2200 kg/m³ for fluoropolymer sensing-cable materials
الموصلية الحرارية0.20-0.30 W/(m·K) for fluoropolymer cable insulation
إنهاء السطحWhite controller with blue status labels and white-yellow braided sensing cable
نوع المشتركSupervised quick-connect sensing cable with end terminator and removable alarm terminals
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

Zone cable or point probeMultiple sensing zonesLeak and trouble relaysModbus or BACnet gateway

Planning a Water Leak Sensor specification?