Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Systèmes de contrôle des salles blanches et de surveillance environnementale

Capteur de fuite d'eau par

A supervised leak sensor that detects conductive liquid along a cable or zone probe near cleanroom utilities and reports an alarm before water spreads.
  • Sensing Cable or Zone Probe
  • Supervised Circuit Integrity
  • Fast Local Alarm
  • BMS Relay Output
Demander un devis. Browse les produits

Introduction de produit

The water leak detection sensor monitors the electrical condition of a floor cable, rope sensor or compact zone probe. Contact with conductive liquid changes the sensing circuit and activates the local controller, while supervision identifies cable breaks or disconnected probes separately. The sensing element can be routed around AHU drain pans, humidifiers, chilled-water lines and raised-floor utility paths. Relay or network output sends leak and trouble states to the BMS so response can begin before water reaches clean finishes or sensitive equipment.

Key Features

Flexible sensing cable follows equipment perimeters and long utility routes.

Circuit supervision distinguishes a leak alarm from a broken or disconnected sensor.

Resettable sensing elements can return to service after cleaning and drying.

Separate relay or network states report leak, cable fault and controller health.

Préoccupations du client produit

A useful leak system must cover the likely water path, remain serviceable and signal cable damage before an actual leak occurs.

A point probe detects water only after it reaches one small location.A sensing cable follows the full perimeter or lowest likely flow path.
A disconnected cable leaves the area unprotected without warning.Supervised end-of-line monitoring creates a distinct trouble alarm for circuit loss.
The sensor must be discarded after a minor clean-water leak.A resettable cable can be wiped, dried and returned to monitoring service.
Water spreads under equipment before staff find the source zone.Zoned circuits and clear controller labels narrow the response area quickly.

Les applications typiques

AHU and humidifier roomsCleanroom utility chasesRaised-floor process areasChilled-water and drain lines

Paramètres techniques

Typical construction values for a cleanroom water leak sensor and zone controller are listed below.

Matériaux de baseConductive polymer sensing cable with fluoropolymer braid and polycarbonate zone controller
Panneau épaisseur35-70 mm controller depth
Largeur effective90-160 mm controller width
Longueur maximaleSensing cable zones up to 30000 mm
Acier face épaisseur0-1.0 mm; optional stainless mounting plate
Densité Core1700-2200 kg/m³ for fluoropolymer sensing-cable materials
Conductivité thermique0.20-0.30 W/(m·K) for fluoropolymer cable insulation
surface finieWhite controller with blue status labels and white-yellow braided sensing cable
Type jointSupervised quick-connect sensing cable with end terminator and removable alarm terminals
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

Zone cable or point probeMultiple sensing zonesLeak and trouble relaysModbus or BACnet gateway

Planning a Water Leak Sensor specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe
Email nous WhatsApp WeChat

Accueil

Produits

Actualités

À propos

Contact